74ACT11257_09 Datasheet, PDF (4/13 Pages) Texas Instruments – QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER WITH 3-STATE OUTPUTS | |||
|
◁ |
74ACT11257
QUADRUPLE 2-LINE TO 1-LINE DATA SELECTOR/MULTIPLEXER
WITH 3-STATE OUTPUTS
SCAS053B â JANUARY 1989 â REVISED APRIL 1996
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETERS
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
MIN MAX
IOH = â50 mA
4.5 V 4.4
4.4
5.5 V 5.4
5.4
VOH
IOH = â24 mA
IOH = â75 mA{
4.5 V 3.94
3.8
5.5 V 4.94
4.8
5.5 V
3.85
IOL = 50 mA
4.5 V
5.5 V
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.44
0.36
0.44
IOL = 75 mA{
5.5 V
1.65
IOZ
VO = VCC or GND
5.5 V
±0.5
±5
II
VI = VCC or GND
5.5 V
±0.1
±1
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
80
DICCâ¡
One input at 3.4 V,
Other inputs at VCC or GND 5.5 V
0.9
1
Ci
VI = VCC or GND
5V
3.5
Co
VO = VCC or GND
5V
8
â Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
â¡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to VCC.
UNIT
V
V
mA
mA
mA
mA
pF
pF
switching characteristics over recomended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Figure 1)
PARAMETER
tPLH
tPHL
tPLH
tPHL
tPZH
tPZL
tPHZ
tPLZ
FROM
(INPUT)
A or B
A /B
OE
OE
TO
(OUTPUT)
Y
Any Y
Any Y
Any Y
TA = 25°C
MIN TYP MAX
1.5 4.4 6.4
1.5
5
8
1.5 4.7 7.6
1.5 5.7 8.5
1.5 4.2 6.9
1.5 5.5 8.7
1.5 5.7 7.6
1.5
6 7.9
MIN MAX UNIT
1.5 6.9
ns
1.5 8.7
1.5 8.2
ns
1.5 9.4
1.5 7.3
ns
1.5 9.6
1.5 8.4
ns
1.5 8.5
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd Power dissipation capacitance
Outputs enabled
Outputs disabled
TEST CONDITIONS
CL = 50 pF, f = 1 MHz
TYP UNIT
41
pF
13
4
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |