74AC11378_10 Datasheet, PDF (4/8 Pages) Texas Instruments – HEX D-TYPE FLIP FLOP WITH ENABLE, POSITIVE EDGE TRIGGER | |||
|
◁ |
74AC11378
HEX D-TYPE FLIP-FLOP
WITH CLOCK ENABLE
SCAS150 â APRIL 1991 â REVISED APRIL 1993
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
3 V 2.9
IOH = â 50 µA
4.5 V 4.4
5.5 V 5.4
VOH
IOH = â 4 mA
IOL = â 24 mA
IOH = â 75 mAâ
3 V 2.58
4.5 V 3.94
5.5 V 4.94
5.5 V
3V
0.1
IOL = 50 µA
4.5 V
0.1
5.5 V
0.1
VOL
IOL = 12 mA
3V
0.36
IOL = 24 mA
4.5 V
0.36
5.5 V
0.36
IOL = 75 mAâ
5.5 V
II
VI = VCC or GND
5.5 V
± 0.1
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
Ci
VI = VCC or GND
5V
4
â Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
MIN MAX UNIT
2.9
4.4
5.4
2.48
V
3.8
4.8
3.85
0.1
0.1
0.1
0.44 V
0.44
0.44
1.65
±1 µA
80 µA
pF
timing requirements over recommended operating free-air temperature range, VCC = 3.3 V ± 0.3 V
(unless otherwise noted) (see Figure 1)
fclock
tw
tsu
Clock frequency
Pulse duration
Setup time, before CLKâ
th
Hold time, after CLKâ
CLK high or low
Data
CLKEN high or low
Data
CLKEN high or low
TA = 25°C
MIN MAX
0
90
5.5
8
6.5
0
0
MIN MAX UNIT
0
90 MHz
5.5
ns
8
ns
6.5
0
ns
0
timing requirements over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V
(unless otherwise noted) (see Figure 1)
fclock
tw
tsu
Clock frequency
Pulse duration
Setup time, before CLKâ
th
Hold time, after CLKâ
CLK high or low
Data
CLKEN high or low
Data
CLKEN high or low
TA = 25°C
MIN MAX
0 110
4
5
4.5
0
0
MIN MAX UNIT
0 110 MHz
4
ns
5
ns
4.5
0
ns
4
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
⢠POST OFFICE BOX 1443 HOUSTON, TEXAS 77251â1443
|
▷ |