Balance Error
The circuit shown in Figure 73 is used to measure the balance error of the main differential amplifier. A network
analyzer is used as the signal source and the measurement device. The output impedance of the network
analyzer is 50Ω and is DC coupled. RIT and RG are chosen to impedance match to 50Ω and maintain the proper
gain. To balance the amplifier, a 49.9Ω resistor to ground is inserted across RIT on the alternate input. The output
is measured using a high impedance differential probe at the summing junction of the two RO resistors, with
respect to ground.
VIN+
Input From 50-Ω
Test Equipment
Cal Diff Probe
RG
RIT
VIN-
No Connection
49.9 Ω
Installed to Balance
Amplifier
0.22 μF
RG
RIT
RF
RO
VS+
+
VOCM
–
VOUT–
THS4531
VS–
VOUT+
RO
RF
Measure With
Diff Probe Here
Figure 73. Balance Error Test Circuit
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Link(s): THS4531
Submit Documentation Feedback