TLC548C_14 Datasheet, PDF (3/20 Pages) Texas Instruments – 8-BIT ANALOG-TO-DIGITAL CONVERTERS WITH SERIAL CONTROL
operating sequence
TLC548C, TLC548I, TLC549C, TLC549I
8-BIT ANALOG-TO-DIGITAL CONVERTERS
WITH SERIAL CONTROL
SLAS067C – NOVEMBER 1983 – REVISED SEPTEMBER 1996
I/O
CLOCK
tsu(CS)
CS
12345678
Access
Cycle B
Sample
Cycle B
12345678
Don’t
Care
tconv
(see Note A)
Access
Cycle C
tsu(CS)
Sample
Cycle C
DATA
OUT
ten
A7 A6 A5 A4 A3 A2 A1 A0
twH(CS)
Hi-Z State
A7
Previous Conversion Data A
MSB
LSB MSB
(see Note B)
ten
Hi-Z State
B7 B6 B5 B4 B3 B2 B1 B0
MSB
B7
Conversion Data B
LSB MSB
NOTES: A. The conversion cycle, which requires 36 internal system clock periods (17 µs maximum), is initiated with the eighth I/O clock pulse
trailing edge after CS goes low for the channel whose address exists in memory at the time.
B. The most significant bit (A7) is automatically placed on the DATA OUT bus after CS is brought low. The remaining seven bits (A6–A0)
are clocked out on the first seven I/O clock falling edges. B7–B0 follows in the same manner.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 V
Input voltage range at any input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Output voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VCC + 0.3 V
Peak input current range (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 10 mA
Peak total input current range (all inputs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 30 mA
Operating free-air temperature range, TA (see Note 2): TLC548C, TLC549C . . . . . . . . . . . . . 0°C to 70°C
TLC548I, TLC549I . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
NOTES: 1. All voltage values are with respect to the network ground terminal with the REF– and GND terminals connected together, unless
otherwise noted.
2. The D package is not recommended below – 40°C.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3