TLC2940
HIGH-PERFORMANCE CMOS VOLTAGE-CONTROLLED OSCILLATOR
SLAS244 – OCTOBER 1999
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage (any supply), VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage range (any input), VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VDD + 0.5 V
Input current (any input), II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output current (any output), IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Continuous total power dissipation (TA = 25°C or below), PD (see Note 2) . . . . . . . . . . . . . . . . . . . . . . 700 mW
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network GND terminals.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 5.6 mW/°C.
recommended operating conditions
PARAMETER
MIN NOM
MAX UNIT
3-V operation
Supply voltage, VDD (any supply, see Notes 3 and 4) 5-V operation
2.85
3
3.15
V
4.75
5
5.25
Input voltage, VI (inputs except VCO IN)
Output current, IO (any output)
VCO control voltage at VCO IN
Lock frequency
3-V operation
5-V operation
RBIAS = 1.5 kΩ
RBIAS = 1.8 kΩ
RBIAS = 2.2 kΩ
RBIAS = 2.7 kΩ
RBIAS = 1.5 kΩ
RBIAS = 2.4 kΩ
RBIAS = 3.3 kΩ
RBIAS = 4.3 kΩ
0
VDD V
0
± 2 mA
1
VDD–0.5 V
42
50
37
47
33
45
28
42
MHz
65
75
50
65
43
56
35
50
VCO oscillation frequency setting resistor, RBIAS
3-V operation
5-V operation
1.5
2.7
kΩ
1.5
4.3
Operating free-air temperature, TA
–20
85 °C
NOTES:
3. It is recommended that the logic supply terminal (LOGIC VDD) and the VCO supply terminal (VCO VDD) should be at the same voltage
and separate from each other.
4. The bypass capacitor should be located as close as possible to each power supply.
5. The FREFINPUT (pin 3) and PFD OUT (pin 4) terminals are input/output terminals preset for logic function respectively. In normal
operation, the FREFINPUT shoud be tied to GND and PDF OUT should be left unconnected (open).
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3