English
Language : 

TL852 Datasheet, PDF (3/7 Pages) Texas Instruments – Overall Gain Adjustable With One External Resistor
TL852
SONAR RANGING RECEIVER
SLSS003 – SEPTEMBER 1983 – REVISED MARCH 1988
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Voltage at any pin with respect to GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Voltage at any pin with respect to VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 7 V to 0.5 V
XIN input current (50% duty cycle) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±60 mA
Continuous power dissipation at (or below) 25°C free-air temperature (see Note 1) . . . . . . . . . . . . 1150 mW
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. This is a stress rating only, and
functional operation of the device at these or any other conditions beyond those indicated in the recommended operating conditions section of this
specification is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: For operation above 25°C, derate linearly at the rate of 9.2 mW/°C.
recommended operating conditions
Supply voltage, VCC
High-level input voltage, VIH
Low-level input voltage, VIL
Bias resistor between BIAS and GND
Operating free-air temperature, TA
GCA, GCB, GCC, GCD
MIN MAX UNIT
4.5 6.8 V
2.1
V
0.6
64
72 kΩ
0
40 °C
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP‡ MAX UNIT
Input clamp voltage at XIN
Open-circuit input voltage at GCA, GCB, GCC, GCD
High-level input current, IIH, into GCA, GCB, GCC, GCD
Low-level input current, IIL, into GCA, GCB, GCC, GCD
Raceive output current
Supply current, ICC
‡ Typical values are at VCC = 5 V and TA = 25°C.
II = 40 mA
II = – 40 mA
VCC = 5 V,
VCC = 5 V,
VCC = 5 V,
IG2IN = – 100 µA,
IG2IN = 100 µA,
II = 0
VIH = 2 V
VIL = 0
VO = 0.3 V
VO = 0.1 V
2.5
V
– 1.5
2.5
V
– 0.5
mA
– 3 mA
1
µA
– 50
45 mA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251–1443
3