English
Language : 

TL7757_14 Datasheet, PDF (3/20 Pages) Texas Instruments – SUPPLY-VOLTAGE SUPERVISOR AND PRECISION VOLTAGE DETECTOR
recommended operating conditions
VCC
Supply voltage
VOH
High-level output voltage
IOL
Low-level output current
TA
Operating free-air temperature
TL7757
SUPPLY-VOLTAGE SUPERVISOR
AND PRECISION VOLTAGE DETECTOR
SLVS041I − SEPTEMBER 1991 − REVISED AUGUST 2003
TL7757C
TL7757I
MIN MAX UNIT
1
7V
15 V
20 mA
0
70
°C
−40
85
electrical characteristics at specified free-air temperature
PARAMETER
TEST CONDITIONS
TL7757C
TA
MIN TYP MAX
VIT−
Negative-going input threshold voltage at VCC
25°C
0°C to 70°C
4.43 4.55 4.67
4.4
4.7
Vhys† Hysteresis at VCC
25°C
0°C to 70°C
40
50
60
30
70
VOL
Low-level output voltage
IOL = 20 mA, VCC = 4.3 V
25°C
0°C to 70°C
0.4 0.8
0.8
IOH
High-level output current
VCC = 7 V,
VOH = 15 V,
See Figure 1
25°C
0°C to 70°C
1
1
Vres‡ Power-up reset voltage
RL = 2.2 kΩ,
VCC slew rate ≤ 5 V/µs
25°C
0°C to 70°C
0.8
1
1.2
ICC
Supply current
VCC = 4.3 V
25°C
0°C to 70°C
1400 2000
2000
VCC = 5.5 V
0°C to 70°C
40
† This is the difference between positive-going input threshold voltage, VIT+, and negative-going input threshold voltage, VIT−.
‡ This is the lowest voltage at which RESET becomes active.
UNIT
V
mV
V
µA
V
µA
switching characteristics at specified free-air temperature
PARAMETER
Propagation delay time, low-to-high-level
tPLH
output
Propagation delay time, high-to-low-level
tPHL
output
tr
Rise time
tf
Fall time
tw(min)
Minimum pulse duration at VCC for output
response
TEST CONDITIONS
VCC slew rate ≤ 5 V/µs,
See Figures 2 and 3
See Figures 2 and 3
VCC slew rate ≤ 5 V/µs,
See Figures 2 and 3
See Figures 2 and 3
TA
25°C
0°C to 70°C
25°C
0°C to 70°C
25°C
0°C to 70°C
25°C
0°C to 70°C
25°C
0°C to 70°C
TL7757C
MIN TYP MAX
3.4
5
5
2
5
5
0.4
1
1
0.05
1
1
5
5
UNIT
µs
µs
µs
µs
µs
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265