English
Language : 

TL720M05-Q1 Datasheet, PDF (3/14 Pages) Texas Instruments – LOW-DROPOUT VOLTAGE REGULATOR
TL720M05-Q1
www.ti.com
SGLS380D – SEPTEMBER 2008 – REVISED JULY 2012
ABSOLUTE MAXIMUM RATINGS(1)
over operating free-air temperature range (unless otherwise noted)
VI
Input voltage range(2)
VO
Output voltage range
θJA
Package thermal impedance, junction to free air(3) (4)
KTT package
KVU package
MIN
MAX UNIT
–42
45 V
–1
40 V
26.9
°C/W
38.6
TJ
Operating virtual-junction temperature range
Tstg
Storage temperature range
–40
150 °C
–65
150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to the network ground terminal.
(3) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
VI
Input voltage
TA
Operating free-air temperature
TJ
Operating virtual-junction temperature
MIN
MAX UNIT
5.5
42 V
–40
125 °C
–40
150 °C
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range, VI = 13.5 V, TJ = −40°C to 150°C (unless otherwise noted)
(see Figure 1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
VO
Output voltage
IO
Output current limit
IQ
Current consumption
Iq = II − IO
VDO
PSRR
DVO
DT
Dropout voltage(1)
Load regulation
Line regulation
Power-supply ripple rejection
Temperature output-voltage drift
IO = 5 mA to 400 mA, VI = 6 V to 28 V
IO = 5 mA to 200 mA, VI = 6 V to 40 V
IO = 1 mA
TJ = 25°C
TJ ≤ 85°C
IO = 250 mA
IO = 400 mA
IO = 300 mA, Vdo = VI − VO
IO = 5 mA to 400 mA
ΔVI = 8 to 32 V, IO = 5 mA
fr = 100 Hz, Vr = 0.5 Vpp
4.9
5.0
5.1
4.9
5.0
5.1
450
700
950
100
220
100
220
5
10
12
22
250
500
15
30
–15
5
15
60
0.5
UNIT
V
mA
μA
mA
mV
mV
mV
dB
mV/K
(1) Measured when the output voltage VO has dropped 100 mV from the nominal value obtained at VI = 13.5 V
Copyright © 2008–2012, Texas Instruments Incorporated
Submit Documentation Feedback
3