English
Language : 

TL1451A-Q1 Datasheet, PDF (3/24 Pages) Texas Instruments – DUAL PULSE-WIDTH-MODULATION CONTROL CIRCUITS
ą
TL1451A-Q1
DUAL PULSEĆWIDTHĆMODULATION CONTROL CIRCUITS
ą
SGLS304A − JUNE 2005 − REVISED JUNE 2008
absolute maximum ratings over operating free-air temperature range†
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 V
Amplifier input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V
Collector output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 V
Collector output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 mA
Continuous power total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
PACKAGE
PW
TA ≤ 25°C
POWER RATING
838 mW
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
6.7 mW/°C
TA = 70°C
POWER RATING
536 mW
TA = 85°C
POWER RATING
436 mW
TA = 125°C
POWER RATING
168 mW
recommended operating conditions
Supply voltage, VCC
Amplifier input voltage, VI
Collector output voltage, VO
Collector output current, IO
Current into feedback terminal
Feedback resistor, RF
Timing capacitor, CT
Timing resistor, RT
Oscillator frequency
Operating free-air temperature, TA
MIN
3.6
1.05
100
150
5.1
1
− 40
MAX
50
1.45
50
20
45
15000
100
500
125
UNIT
V
V
V
mA
µA
kΩ
pF
kΩ
kHz
°C
www.ti.com