English
Language : 

SN95176B Datasheet, PDF (3/15 Pages) Texas Instruments – DIFFERENTIAL BUS TRANSCEIVER
ą
SN95176B
DIFFERENTIAL BUS TRANSCEIVER
ą
SGLS026A − MARCH 1989 − REVISED JUNE 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Voltage at any bus terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −10 V to 15 V
Enable input voltage, VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 110°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Case temperature for 60 seconds, TC: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG or W package . . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential input/output bus voltage, are with respect to network ground terminal.
PACKAGE
FK
JG
W
TA ≤ 25°C
POWER RATING
1375 mW
1050 mW
1000 mW
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
11.0 mW/°C
8.4 mW/°C
TA = 70°C
POWER RATING
880 mW
672 mW
TA = 85°C
POWER RATING
715 mW
546 mW
TA = 110°C
POWER RATING
440 mW
336 mW
8.0 mW/°C
640 mW
520 mW
320 mW
recommended operating conditions
MIN TYP MAX
Supply voltage, VCC
Voltage at any bus terminal (separately or common-mode), VI or VIC
4.75
5 5.25
12
−7
High-level input voltage, VIH
D, DE, and RE
Low-level input voltage, VIL
D, DE, and RE
Differential input voltage, VID (see Note 2)
High-level output current, IOH
Driver
Receiver
2
0.8
± 12
− 60
− 400
Driver
60
Low-level output current, IOL
Receiver
8
Operating free-air temperature, TA
− 40
110
NOTE 2: Differential-input/output bus voltage is measured at the noninverting terminal A with respect to the inverting terminal B.
UNIT
V
V
V
V
V
mA
µA
mA
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
2−3