English
Language : 

SN75128 Datasheet, PDF (3/9 Pages) Texas Instruments – EIGHT-CHANNEL LINE RECEIVERS
ą
SN75128, SN75129
EIGHTĆCHANNEL LINE RECEIVERS
ą
SLLS076B − JANUARY 1977 − REVISED MAY 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage range, VI (A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.15 V to 7 V
Input voltage, VI (S) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to network ground terminal.
PACKAGE
N
DISSIPATION RATING TABLE
TA ≤ 25°C
POWER RATING
1150 mW
DERATING FACTOR
ABOVE TA = 25°C
9.2 mW/°C
TA = 70°C
POWER RATING
736 mW
recommended operating conditions
Supply voltage, VCC
A
High-level input voltage, VIH
S
A
Low-level input voltage, VIL
S
High-level output current, IOH
Low-level output current, IOL
Operating free-air temperature, TA
MIN NOM MAX UNIT
4.5
5 5.5 V
1.7
V
2
0.7
V
0.7
−0.4 mA
16 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VOH High-level output voltage
VCC = 4.5 V, VIL = 0.7 V,
IOH = − 0.4 mA
2.4 3.1
V
VOL Low-level output voltage
VCC = 4.5 V, VIH = 1.7 V,
IOL = 16 mA
0.4 0.5 V
VIK Input clamp voltage
S VCC = 4.5 V, II = − 18 mA
−1.5 V
IIH High-level input current
A VCC = 5.5 V, VI = 3.11 V
S VCC = 5.5 V, VI = 2.7 V
0.3 0.42 mA
20 µA
IIL
Low-level input current
IOS Short-circuit output current‡
A VCC = 5.5 V,
S VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.15 V
VI = 0.4 V
VO = 0
30 µA
−0.4 mA
− 18
−60 mA
rI
Input resistance
VCC = 4.5 V, 0 V or open,
∆VI = 0.15 V to 4.15 V
7
20 kΩ
SN75128 VCC = 5.5 V, Strobe at 2.4 V, All A inputs at 0.7 V
19
31
ICC Supply current
SN75129 VCC = 5.5 V, Strobe at 0.4 V, All A inputs at 0.7 V
SN75128 VCC = 5.5 V, Strobe at 2.4 V, All A inputs at 4 V
19
31
mA
32
53
SN75129 VCC = 5.5 V,
† All typical values are at VCC = 5 V, TA = 25°C.
‡ Not more than one output should be shorted at a time.
Strobe at 0.4 V, All A inputs at 4 V
32
53
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
2−3