English
Language : 

SN74BCT29826 Datasheet, PDF (3/7 Pages) Texas Instruments – 8-BIT BUS-INTERFACE FLIP-FLOPS WITH 3-STATE OUTPUTS
logic diagram (positive logic)
1
OE1
2
OE2
23
OE3
CLR 11
14
CLKEN
13
CLK
3
1D
SN54BCT29826, SN74BCT29826
8ĆBIT BUSĆINTERFACE FLIPĆFLOPS
WITH 3ĆSTATE OUTPUTS
SCBS076A − NOVEMBER 1991 − REVISED NOVEMBER 1993
R
C1
1D
22
1Q
Pin numbers shown are for the DW, JT, NT, and W packages.
To Seven Other Channels
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage range applied to any output in the disabled or power-off state, VO . . . . . . . . . . . . . . . . −0.5 V to 5.5 V
Voltage range applied to any output in the high state, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA
Current into any output in the low state, IO: SN54BCT29826 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA
SN74BCT29826 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
Operating free-air temperature range: SN54BCT29826 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74BCT29826 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
SN54BCT29826
MIN NOM MAX
4.5
5 5.5
2
0.8
−18
−15
24
− 55
125
SN74BCT29826
MIN NOM MAX
4.5
5 5.5
2
0.8
−18
− 24
48
0
70
UNIT
V
V
V
mA
mA
mA
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77251−1443
2−3