English
Language : 

PTB48600A Datasheet, PDF (3/10 Pages) Texas Instruments – 85 W Dual Complementary-Output DC/DC Converter for DSL
Not Recommended for New Designs
PTB48600 —48-V Input
85 W Dual Complementary-Output
DC/DC Converter for DSL
SLTS239 JANUARY 2005
Specifications (Unless otherwise stated, TA =25°C, VI =48 V, CI =0 µF, ±CO =0 µF, |+IO | = |–IO |, and |±IO | =0.5 |±IO |max)
PTB48600A
Characteristic
Symbol
Conditions
Min
Typ
Max
Units
Output Power
Output Current
Output Load Imbalance
Output Voltage
Temperature Variation
Line Regulation
Load Regulation
Efficiency
PO
Total output power from ±VO
0
—
|±IO |
Over VI range, |+IO | – |–IO | ≤ 0.1 A
0
—
|+IO | – |–IO |
|+IO | ≥0.1 A, |–IO | ≥ 0.1 A
0
—
|±VO |
Inlcudes
–40 ≤TA
set-point,
≤+85°C
line,
|+IO
|
–
|–IO
|
≤
0.1
A
4.75 (2)
5
∆RegTEMP
–40 ≤TA ≤ +85°C, |±IO| =0.1 A
+VO
—
±1
–VO
—
±1
∆RegLINE
Over VI range, balanced load
±VO
—
±0.1
∆RegLOAD
Over ±IO range, balanced load
±VO
—
±0.2
η
—
85
85 (1)
8.5 (2)
1 (3)
5.25 (2)
—
—
±0.4
±0.4
—
W
A
A
V
%Vo
%Vo
%Vo
%
Vo Ripple (pk-pk)
Transient Response
Over Current Threshold
±VR
tTR
∆VTR
|±IO| trip
20 MHz bandwidth,
CO =10 µF tantalum capacitor
0.1 A/µs load step, 50% to 75% ±IOmax
|±VO | over/undershoot
VI =36 V, |+IO| = |–IO|,
reset followed by auto-recovery
—
20
30 (4)
mVpp
—
30
—
µs
—
±1
—
%Vo
9
10
12
A
Short Circuit Current
Output Voltage Adjust Range
Switching Frequency
Under-Voltage Lockout
On/Off Enable (pin 3)
Input High Voltage
Input Low Voltage
Input Low Current
Standby Input Current
Start-up Time
Internal Input Capacitance
External Output Capacitance
Reliability
|±VO | adj
ƒS
VI on
VI off
VIH
VIL
IIL
II standby
tON
CI
±CO
MTBF
Continuous over-current trip,
|±IO |PK
—
|+IO | = |–IO |
Duty —
|+VO | and |–VO | adjust simulataneously
3.31
Over VI and IO ranges
440
VI increasing
—
VI decreasing
—
Referenced to –VI (pin 4)
+3.6
–0.2
—
pin 3 open circuit
—
|±IO | =1 A, |±VO | rising 0 to 0.95 |±VO | typ
6
—
Capacitance from either output to COM
0
Per Telcordia SR-332
2.8
50% stress, TA =40°C, gnd benign
16
10
—
470 (5)
33
32
—
—
—
2
10
3
—
—
—
—
6
500
—
—
+75 (6)
+0.8
–1
—
22
—
5,000 (7)
—
A
%
V
kHz
V
V
mA
mA
ms
µF
µF
106 Hrs
Notes: (1) See Safe Operating Area curves or contact the factory for the appropriate derating.
(2) Under balanced load conditions, load current flowing out of +VO is balanced to within ±0.1 A of that flowing into –VO.
(3) A load imbalance is the difference in current flowing from +VO to –VO. The module can operate with a higher imbalance but with reduced specifications.
(4) Output voltage ripple is measured with a 10 µF tantalum capacitor connected from +VO (pin 5) or –VO (pin 8), to COM (pin 6).
(5) This is the free-running frequency. The module can be made to synchronize with the PTB48500 when both modules are used together in a system.
(6) The On/Off Enable (pin 3) has an internal pull-up and may be controlled with an open-collector (or open-drain) transistor. The input is diode protected
and may be connected to +VI. The open-circuit voltage is 5 V max. If it is left open circuit the converter will operate when input power is applied.
(7) Electrolytic capacitors with very low equivalent series resistance (ESR) may induce instability when used on the output. Consult the factory before using
capacitors with organic, or polymer-aluminum type electrolytes.
For technical support and further information visit http://power.ti.com