English
Language : 

PTB48520W Datasheet, PDF (3/18 Pages) Texas Instruments – 25-A, 48-V INPUT ISOLATED DC/DC CONVERTER WITH AUTO-TRACK™ SEQUENCING
www.ti.com
PACKAGE SPECIFICATIONS
Weight
Flammability
Meets UL94V-O
PTB48520W (Suffixes AH and AS)
Mechanical shock
Per Mil-STD-883D, Method 2002.3
1 msec, 1/2 Sine, mounted
Mechanical vibration
Mil-STD-883D, Method 2007.2
20-2000 Hz, PCB mounted
(1) Qualification limit.
PTB48520W
SLTS233A – NOVEMBER 2004 – REVISED APRIL 2005
28.5 grams
Horizontal T/H (Suffix AH)
Horizontal SMD (Suffix AS)
Horizontal T/H (Suffix AH)
Horizontal SMD (Suffix AS)
250 Gs (1)
150 Gs (1)
15 Gs (1)
5 Gs (1)
ELECTRICAL CHARACTERISTICS
(Unless otherwise stated, TA = 25°C, VI = 48 V, VO = 3.3 V, CO = 0 µF, and IO = IOmax)
PARAMETER
TEST CONDITIONS
MIN
IO
Output current
Over VI range
Sum total IO Bus + IO Seq
VI
Input voltage range
Over IO range
Set-point voltage tolerance
IO Bus
0
IO Seq
0
0
36
Temperature variation
-40°C ≤ TA ≤ 85°C
Line regulation
VO
Load regulation
Over VI range
Over IO range
Total output voltage variation Includes set-point, line, load, –40°C ≤ TA≤ 85°C
Adjust range
Over VI range
1.8
RSET = 887 Ω, VO = 3.3 V
η
Efficiency
IO = 15 A
RSET = 6.98 kΩ, VO = 2.5 V
RSET = 35.7 kΩ, VO = 2.0 V
RSET = open cct. VO = 1.8 V
VO Ripple (peak-to-peak)
20 MHz bandwidth
1 A/µs load step, 50% to 100% IOmax
Transient Response
Recovery time
Track input (pin 4)
VO over/undershoot
Input current
Pin connected to VO COM
Open-circuit voltage
0
Input slew rate limits
0.1 (4)
Referenced to -VI (pin 3)
Output enable input (pin 2)
Input high voltage (VIH)
2
Input low voltage (VIL)
-0.2
Input low current (IIL)
Standby input current
Pin 2 open
No-load input current
Pins 2 and 3 connected, IO Tot = 0
Overcurrent threshold, IO (tot) Shutdown, followed by autorecovery
TYP
48
±0.6 (3)
±0.8
±1
±1
±1.5
91%
90%
89%
88%
20
75
±3
–480
2
50
40
MAX
25 (1)
10 (1) (2)
25
75
±3 (3)
3.6
UNIT
A
A
V
%Vo
%Vo
mV
mV
%Vo
V
mVpp
-0.13
Vo Bus
1
µs
%Vo
mA
V
V/ms
Open (5)
V
0.8
µA
mA
mA
A
(1) See temperature derating curves for safe operating area (SOA), or consult factory for appropriate derating.
(2) When load current is supplied from the VO Seq output, the module exhibits higher power dissipation and slightly lower operating
efficiency.
(3) The set-point voltage tolerance is affected by the tolerance and stability of RSET. The stated limit is unconditionally met if RSET has a
tolerance of 1%, with 100 ppm/°C temperature stability.
(4) When controlling the Track input from an external source, the slew rate of the applied signal must be greater than the minimum limit.
Failure to allow the voltage to completely rise to the voltage at the VO (bus) output, at no less than the minimum specified rate, may
thermally overstress the converter.
(5) The VO Enable input has an internal pull-up, and if left open the converter output isturned off. A discrete MOSFET or bipolar transistor is
recommended to control this input. The open-circuit voltage is approximately 20% of the input voltage. If the output enable feature is not
used, this pin should be permanently connected to –VI. See the application information for other interface considerations.
3