English
Language : 

LP2901-Q1_14 Datasheet, PDF (3/10 Pages) Texas Instruments – LOW-POWER QUAD DIFFERENTIAL COMPARATOR
LP2901-Q1
www.ti.com................................................................................................................................................ SLCS148A – SEPTEMBER 2005 – REVISED APRIL 2008
Recommended Operating Conditions
VCC
Supply voltage
VIC
Common-mode input voltage
VI
Input voltage
TA
Operating free-air temperature
VCC = 5 V
VCC = 30 V
VCC = 5 V
VCC = 30 V
MIN MAX UNIT
3
30 V
0
3
V
0
28
0
3
V
0
28
–40
85 °C
Electrical Characteristics
VCC = 5 V, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VIO Input offset voltage
VCC = 5 V to 30 V, VO = 2 V(2),
RS = 0
IIO
Input offset current
IIB
Input bias current(3)
VICR
AVD
Common-mode
input voltage range
Large-signal differential
voltage amplification
Single supply
VCC = 15 V, RL = 15 kΩ
TA (1)
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
MIN
0 to VCC – 1.5
0 to VCC – 2
TYP MAX UNIT
±2
±5
mV
±9
±0.5
±5
nA
±1 ±15
–2.5 –25
nA
–4 –40
V
500
V/mV
Output sink current
Output leakage current
VID Differential input voltage
ICC
Supply current
VI– = 1 V,
VI+ = 0
VO = 2 V(4)
VO = 0.4 V
VI+ = 1 V,
VI– = 0
VO = 5 V
VO = 30 V
VI ≤ 0 (or VCC– on split supplies)
RL = ∞, All comparators
25°C
Full range
25°C
25°C
Full range
20
30
15
mA
0.2 0.7
0.1
nA
1 µA
36 V
60 100 µA
(1) Full range is –40°C to 125°C.
(2) VIO is measured over the full common-mode input voltage range.
(3) Because of the p-n-p input stage, the direction of the current is out of the device. This current essentially is constant (i.e., independent of
the output state). No loading change exists on the reference or input lines as long as the common-mode input voltage range is not
exceeded.
(4) The output sink current is a function of the output voltage. These devices have a bimodal output section that allows them to sink (via a
Darlington connection) large currents at output voltages greater than 1.5 V and smaller currents at output voltages less than 1.5 V.
Switching Characteristics
VCC = 5 V, TA = 25°C, RL connected to 5 V through 5.1 kΩ
PARAMETER
TEST CONDITIONS
Large-signal response time
Response time
TTL logic swing, Vref = 1.4 V
TYP UNIT
1.3
µs
8
Copyright © 2005–2008, Texas Instruments Incorporated
Product Folder Link(s): LP2901-Q1
Submit Documentation Feedback
3