English
Language : 

DS96173_15 Datasheet, PDF (3/11 Pages) Texas Instruments – RS-485/RS-422 Quad Differential Line Receivers
DS96173 - Obsolete
DS96175 - Not Recommended For New Designs
DS96173, DS96175
www.ti.com
SNLS391C – JUNE 1998 – REVISED APRIL 2013
Electrical Characteristics(1)(2)
over recommended temperature, common mode input voltage, and supply voltage ranges, unless otherwise specified
Parameter
Test Conditions
Min
Typ
Max
Units
VTH
VTL
VT+ − VT−
Differential Input High Threshold Voltage
Differential Input(3) Low Threshold Voltage
Hysteresis (4)
VO = 2.7V, IO = − 0.4 mA
VO = 0.5V, IO = 16 mA
VCM = 0V
0.2
V
−0.2
V
50
mV
VIH
Enable Input Voltage HIGH
2.0
V
VIL
Enable Input Voltage LOW
0.8
V
VIC
Enable Input Clamp Voltage
II = −18 mA
−1.5
V
VOH
Output Voltage HIGH
VID = 200 mV, IOH = −400 μA
2.7
V
VOL
Output Voltage LOW
VID = −200 mV
IOL = 8 mA
IOL = 16 mA
0.45
V
0.50
IOZ
High Impedance State Output
II
Line Input Current(5)
VO = 0.4V to 2.4V
Other Input = 0V
VI = 12V
VI = −7V
±20
μA
1.0
mA
−0.8
IIH
Enable Input Current HIGH
VIH = 2.7V
20
μA
IIL
Enable Input Current LOW
VIL = 0.4V
−100
μA
RI
Input Resistance
IOS
Short Circuit Output Current
See (6)
12
kΩ
−15
−85
mA
ICC
Supply Current
Outputs Disabled
75
mA
(1) Unless otherwise specified Min/Max limits apply across the 0°C to +70°C range for the DS96173/DS96175. All typicals are given for VCC
= 5V and TA = 25°C.
(2) All currents into the device pins are positive; all currents out of the device pins are negative. All voltages are reference to ground unless
otherwise specified.
(3) The algebraic convention, when the less positive (more negative) limit is designated minimum, is used in this data sheet for common
mode input voltage and threshold voltage levels only.
(4) Hysteresis is the difference between the positive-going input threshold voltage, VT+, and the negative going input threshold voltage, VT−.
(5) Refer to EIA Standards RS-485 for exact conditions.
(6) Only one output at a time should be shorted.
Switching Characteristics
VCC = 5V, TA = 25°C
Parameter
tPLH
Propagation Delay Time,
Low to High Level Output
tPHL
Propagation Delay Time,
High to Low Level Output
tPZH
Output Enable Time to High Level
tPZL
Output Enable Time to Low Level
tPHZ
Output Disable Time from High Level
tPLZ
Output Disable Time from Low Level
Test Conditions
VID = −2.5V to 2.5V,
CL = 15 pF, Figure 1
CL = 15 pF, Figure 2
CL = 15 pF, Figure 3
CL = 5 pF, Figure 2
CL = 5 pF, Figure 3
Min
Typ
Max
Units
15
25
ns
15
25
ns
15
22
ns
15
22
ns
14
30
ns
24
40
ns
Copyright © 1998–2013, Texas Instruments Incorporated
Product Folder Links: DS96173 DS96175
Submit Documentation Feedback
3