English
Language : 

CY54FCT377T_14 Datasheet, PDF (3/12 Pages) Texas Instruments – 8-BIT REGISTERS
CY54FCT377T, CY74FCT377T
8-BIT REGISTERS
SCCS023A – MAY 1994 – REVISED OCTOBER 2001
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range to ground potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC output voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC output current (maximum sink current/pin) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mA
Package thermal impedance, θJA (see Note 1): Q package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68°C/W
SO package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58°C/W
Ambient temperature range with power applied, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 135°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 2)
CY54FCT377T
MIN NOM MAX
VCC Supply voltage
4.5
5 5.5
VIH High-level input voltage
2
VIL Low-level input voltage
0.8
IOH High-level output current
–12
IOL Low-level output current
32
TA Operating free-air temperature
–55
125
NOTE 2: All unused inputs of the device must be held at VCC or GND to ensure proper device operation.
CY74FCT377T
MIN NOM MAX
4.75
5 5.25
2
0.8
–32
64
–40
85
UNIT
V
V
V
mA
mA
°C
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3