English
Language : 

CD74ACT32-Q1 Datasheet, PDF (3/9 Pages) Texas Instruments – QUADRUPLE 2-INPUT POSITIVE-OR GATE
CD74ACT32-Q1
QUADRUPLE 2-INPUT POSITIVE-OR GATE
SCHS351A − JANUARY 2004 − REVISED JANUARY 2008
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
−40°C to
125°C
UNIT
MIN MAX MIN MAX
VOH
VI = VIH or VIL
VOL
II
ICC
DICC‡
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC − 2.1 V
IOH = −50 µA
IOH = −24 mA
IOH = −50 mA†
IOL = 50 µA
IOL = 24 mA
IOL = 50 mA†
IO = 0
4.5 V
4.5 V
5.5 V
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
4.5 V to
5.5 V
4.4
4.4
3.94
3.7
V
3.85
0.1
0.1
0.36
0.5 V
1.65
±0.1
±1 µA
4
80 µA
2.4
3 mA
Ci
10
10 pF
† Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 75-Ω transmission-line drive capability at 125°C.
‡ Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
All
UNIT LOAD
0.42
Unit load is ∆ICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
−40°C to
125°C
MIN MAX
UNIT
tPLH
tPHL
A or B
3 12.1
Y
ns
3 12.1
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance
TYP UNIT
47
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3