English
Language : 

CD54ACT32 Datasheet, PDF (3/13 Pages) Texas Instruments – QUADRUPLE 2-INPUT POSITIVE-OR GATES
CD54ACT32, CD74ACT32
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCHS342 – MARCH 2003
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
–55°C to
125°C
MIN MAX
–40°C to
85°C
MIN MAX
UNIT
VOH
VI = VIH or VIL
VOL
II
ICC
DICC‡
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC – 2.1 V
IOH = –50 µA
IOH = –24 mA
IOH = –50 mA†
IOH = –75 mA†
IOL = 50 µA
IOL = 24 mA
IOL = 50 mA†
IOL = 75 mA†
IO = 0
4.5 V
4.5 V
5.5 V
5.5 V
4.5 V
4.5 V
5.5 V
5.5 V
5.5 V
5.5 V
4.5 V to
5.5 V
4.4
4.4
4.4
3.94
3.7
3.8
V
3.85
3.85
0.1
0.1
0.1
0.36
0.5
0.44
V
1.65
1.65
±0.1
±1
±1 µA
4
80
40 µA
2.4
3
2.8 mA
Ci
10
10
10 pF
† Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive capability at 125°C.
‡ Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE
INPUT
All
UNIT LOAD
0.42
Unit Load is ∆ICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–55°C to
125°C
MIN MAX
–40°C to
85°C
MIN MAX
UNIT
tPLH
tPHL
A or B
3 12.1 3.1
11
Y
ns
3 12.1 3.1
11
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance
TYP UNIT
47
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3