CD54AC32 Datasheet, PDF (3/14 Pages) Intersil Corporation – Quad 2-Input OR Gate | |||
|
◁ |
CD54AC32, CD74AC32
QUADRUPLE 2-INPUT POSITIVE-OR GATES
SCHS343 â MARCH 2003
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN MAX
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
UNIT
1.5 V
1.4
1.4
1.4
IOH = â50 µA
3V
2.9
2.9
2.9
4.5 V
4.4
4.4
4.4
VOH
VI = VIH or VIL
IOH = â4 mA
IOH = â24 mA
IOH = â50 mAâ
IOH = â75 mAâ
3V
4.5 V
5.5 V
5.5 V
1.5 V
2.58
2.4
2.48
V
3.94
3.7
3.8
3.85
3.85
0.1
0.1
0.1
IOL = 50 µA
3V
4.5 V
0.1
0.1
0.1
0.1
0.1
0.1
VOL
VI = VIH or VIL
IOL = 12 mA
3V
0.36
0.5
0.44 V
IOL = 24 mA
IOL = 50 mAâ
IOL = 75 mAâ
4.5 V
5.5 V
5.5 V
0.36
0.5
0.44
1.65
1.65
II
VI = VCC or GND
5.5 V
±0.1
±1
±1 µA
ICC
VI = VCC or GND,
IO = 0
5.5 V
4
80
40 µA
Ci
10
10
10 pF
â Test one output at a time, not exceeding 1-second duration. Measurement is made by forcing indicated current and measuring voltage to minimize
power dissipation. Test verifies a minimum 50-⦠transmission-line drive capability at 85°C and 75-⦠transmission-line drive capability at 125°C.
switching characteristics over recommended operating free-air temperature range,
VCC = 1.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
UNIT
tPLH
tPHL
A or B
119
108
Y
ns
119
108
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
â55°C to
125°C
MIN MAX
â40°C to
85°C
MIN MAX
UNIT
tPLH
tPHL
A or B
3.3 13.3 3.4 12.1
Y
ns
3.3 13.3 3.4 12.1
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3
|
▷ |