English
Language : 

8404601DA Datasheet, PDF (3/20 Pages) Texas Instruments – QUADRUPLE 2-INPUT EXCLUSIVE-OR GATES
SN54HC86, SN74HC86
QUADRUPLE 2-INPUT EXCLUSIVE-OR GATES
SCLS100E – DECEMBER 1982 – REVISED AUGUST 2003
recommended operating conditions (see Note 3)
SN54HC86
MIN NOM MAX
SN74HC86
UNIT
MIN NOM MAX
VCC Supply voltage
2
5
6
2
5
6V
VCC = 2 V
1.5
1.5
VIH High-level input voltage
VCC = 4.5 V
3.15
3.15
V
VCC = 6 V
4.2
4.2
VCC = 2 V
0.5
0.5
VIL
Low-level input voltage
VCC = 4.5 V
1.35
1.35 V
VCC = 6 V
1.8
1.8
VI
Input voltage
0
VCC
0
VCC V
VO
Output voltage
0
VCC
0
VCC V
VCC = 2 V
1000
1000
∆t/∆v Input transition rise/fall time
VCC = 4.5 V
500
500 ns
VCC = 6 V
400
400
TA
Operating free-air temperature
–55
125 –40
85 °C
NOTE 3: All unused inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VOH
VI = VIH or VIL
VOL
VI = VIH or VIL
II
VI = VCC or 0
ICC
VI = VCC or 0,
Ci
IOH = –20 µA
IOH = –4 mA
IOH = –5.2 mA
IOL = 20 µA
IOL = 4 mA
IOL = 5.2 mA
IO = 0
VCC
2V
4.5 V
6V
4.5 V
6V
2V
4.5 V
6V
4.5 V
6V
6V
6V
2 V to 6 V
TA = 25°C
MIN TYP MAX
1.9 1.998
4.4 4.499
5.9 5.999
3.98 4.3
5.48 5.8
0.002 0.1
0.001 0.1
0.001 0.1
0.17 0.26
0.15 0.26
±0.1 ±100
2
3
10
SN54HC86
MIN MAX
1.9
4.4
5.9
3.7
5.2
0.1
0.1
0.1
0.4
0.4
±1000
40
10
SN74HC86
MIN MAX
1.9
4.4
5.9
3.84
5.34
0.1
0.1
0.1
0.33
0.33
±1000
20
10
UNIT
V
V
nA
µA
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265