English
Language : 

74ACT11151 Datasheet, PDF (3/6 Pages) Texas Instruments – 1-OF-8 DATA SELECTOR/MULTIPLEXER
ą
74ACT11151
1ĆOFĆ8 DATA SELECTOR/MULTIPLEXER
ą
SCAS067A − D3349, JULY 1989 − REVISED APRIL 1993
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . − 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
recommended operating conditions
VCC
VIH
VIL
VI
VO
IOH
IOL
Dt /Dv
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature
MIN MAX UNIT
4.5 5.5 V
2
V
0.8 V
0 VCC V
0 VCC V
−24 mA
24 mA
0
10 ns/ V
− 40
85 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
MIN TYP MAX
MIN MAX
IOH = − 50 mA
4.5 V
4.4
4.4
5.5 V
5.4
5.4
VOH
IOH = − 24 mA
IOH = − 75 mA{
IOL = 50 mA
4.5 V 3.94
5.5 V 4.94
5.5 V
4.5 V
5.5 V
3.8
4.8
3.85
0.1
0.1
0.1
0.1
VOL
IOL = 24 mA
4.5 V
5.5 V
0.36
0.44
0.36
0.44
IOL = 75 mA{
5.5 V
1.65
II
VI = VCC or GND
5.5 V
± 0.1
±1
ICC
VI = VCC or GND,
IO = 0
5.5 V
8
80
DICC}
One input at 3.4 V,
Other inputs at GND or VCC
5.5 V
0.9
1
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
‡ This is the increase in supply current for each input that is at one of the specified TTL voltage levels rather than 0 V to VCC.
UNIT
V
V
mA
mA
mA
pF
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2−3