electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
VCC
TA = 25°C
54AC11034
MIN TYP MAX MIN MAX
3V
2.9
2.9
IOH = − 50 µA
4.5 V
4.4
4.4
5.5 V
5.4
5.4
VOH
IOH = − 4 mA
IOH = − 24 mA
IOH = − 50 mA†
IOH = − 75 mA†
3 V 2.58
4.5 V 3.94
5.5 V 4.94
5.5 V
5.5 V
3V
2.4
3.7
4.7
3.85
0.1
0.1
IOL = 50 µA
4.5 V
5.5 V
0.1
0.1
0.1
0.1
VOL
IOL = 12 mA
IOL = 24 mA
3V
4.5 V
5.5 V
0.36
0.5
0.36
0.5
0.36
0.5
IOL = 50 mA†
5.5 V
1.65
IOL = 75 mA†
5.5 V
II
VI = VCC or GND
5.5 V
± 0.1
±1
ICC
VI = VCC or GND, IO = 0
5.5 V
4
80
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
74AC11034
MIN MAX
2.9
4.4
5.4
2.48
3.8
4.8
3.85
0.1
0.1
0.1
0.44
0.44
0.44
1.65
±1
40
UNIT
V
V
µA
µA
pF
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
54AC11034 74AC11034
MIN TYP MAX MIN MAX MIN MAX
tPLH
A
tPHL
1.5 5.7 9.1 1.5 10.7 1.5 10.1
Y
1.5 5.5 8.3 1.5 9.9 1.5 9.2
UNIT
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TA = 25°C
54AC11034 74AC11034
MIN TYP MAX MIN MAX MIN MAX
tPLH
A
tPHL
1.5
4 6.3 1.5 7.4 1.5 6.9
Y
1.5
4 6.2 1.5 7.3 1.5 6.8
UNIT
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance per gate
TEST CONDITIONS
CL = 50 pF,
f = 1 MHz
TYP UNIT
27
pF