English
Language : 

THS4531 Datasheet, PDF (29/54 Pages) Texas Instruments – Ultra Low Power, Rail-to-Rail Output, Fully-Differential Amplifier
www.ti.com
VIN+
Input From 50-Ω
Test Equipment
RG
PD
RIT
0.22 μF
VIN–
No Connection
Installed to Balance
Amplifier
0.22 μF
49.9 Ω
0.22 μF
RG
RIT
THS4531
SLOS358B – SEPTEMBER 2011 – REVISED MARCH 2012
RF
RO
VS+
+
VOCM
–
THS4531
VS–
RO
RF
VOUT–
Output to
Test Equipment
VOUT+
Output to
Test Equipment
Figure 69. Slew Rate, Transient Response, Settling Time, ZO, Overdrive Recovery, VOUT Swing, and Turn-
on/off Test Circuit
Common-Mode and Power Supply Rejection
The circuit shown in Figure 70 is used to measure the CMRR. The signal from the network analyzer is applied
common-mode to the input.
VIN+
Input From 50-Ω
Test Equipment
VIN–
No Connection
RG
RF
RO
0.22 μF
RG
VS+
+
VOCM
–
VS–
VOUT–
THS4531
VOUT+
RO
ROT
RF
RIT
Cal Diff Probe
Measure With
Diff Probe
Figure 70. CMRR Test Circuit
Figure 71 is used to measure the PSRR of VS+ and VS-. The power supply is applied to the network analyzer’s
DC offset input. For both CMRR and PSRR, the output is probed using a high impedance differential probe
across ROT.
Copyright © 2011–2012, Texas Instruments Incorporated
Product Folder Link(s): THS4531
Submit Documentation Feedback