English
Language : 

LDC1312-Q1_16 Datasheet, PDF (28/60 Pages) Texas Instruments – Multi-Channel 12-Bit Inductance to Digital Converter (LDC) for Inductive Sensing
LDC1312-Q1, LDC1314-Q1
SNOSCZ6 – APRIL 2016
8.6.15 Address 0x11, SETTLECOUNT_CH1
www.ti.com
Figure 31. Address 0x11, SETTLECOUNT_CH1
15
14
13
12
11
10
9
8
CH1_SETTLECOUNT
7
6
5
4
3
2
1
0
CH1_SETTLECOUNT
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 26. Address 0x12, SETTLECOUNT_CH1 Field Descriptions
Bit Field
15:0 CH1_SETTLECOUNT
Type
R/W
Reset
Description
0000 0000
0000 0000
Channel 1 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on a Channel 1.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled.
0x0000: Settle Time (tS1)= 32 ÷ fREF1
0x0001: Settle Time (tS1)= 32 ÷ fREF1
0x0002- 0xFFFF: Settle Time (tS1)= (CH1_SETTLECOUNTË£16)
÷ fREF1
8.6.16 Address 0x12, SETTLECOUNT_CH2 (LDC1314 only)
Figure 32. Address 0x12, SETTLECOUNT_CH2
15
14
13
12
11
10
9
8
CH2_SETTLECOUNT
7
6
5
4
3
2
1
0
CH2_SETTLECOUNT
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 27. Address 0x12, SETTLECOUNT_CH2 Field Descriptions
Bit Field
15:0 CH2_SETTLECOUNT
Type
R/W
Reset
Description
0000 0000
0000 0000
Channel 2 Conversion Settling
The LDC will use this settling time to allow the LC sensor to
stabilize before initiation of a conversion on Channel 2.
If the amplitude has not settled prior to the conversion start, an
Amplitude error will be generated if reporting of this type of error
is enabled.
0x0000: Settle Time (tS2)= 32 ÷ fREF2
0x0001: Settle Time (tS2)= 32 ÷ fREF2
0x0002- 0xFFFF: Settle Time (tS2)= (CH2_SETTLECOUNTË£16)
÷ fREF2
28
Submit Documentation Feedback
Copyright © 2016, Texas Instruments Incorporated