English
Language : 

TWL2213CA Datasheet, PDF (27/31 Pages) Texas Instruments – POWER SUPPLY MANAGEMENT IC AND Li-Ion BATTERY CHARGE CONTROL
TWL2213CA
POWER SUPPLY MANAGEMENT IC AND
Li-Ion BATTERY CHARGE CONTROL
SLVS280 – MARCH 2001
APPLICATION INFORMATION
current termination
During the CV mode, the charge cycle is terminated when the charging current is under the programmed
terminated level or when the total charge timer (TCTR) times out. The terminated current level can be
programmed to 10%, 20%, 30%, 40%, or 50% of the charging current at CC mode.
temperature monitoring
The TWL2213 device monitors the battery temperature throughout the charge cycle. The input for ADC
reference voltage is generated by a negative temperature coefficient (NTC) thermistor. The TWL2213 device
compares the ADC input reference voltage to the programmed threshold voltages to determine if charging is
allowed. Three required thresholds are:
D VBOTRH+ Voltage for over-temperature cutoff; charging is suspended.
D VBORTH– Voltage to resume charging function for over-temperature cutoff.
D VBORTL Voltage for low-temperature cutoff; charging is suspended.
Ts (V)
2V
VBOTRL
VBOTRH–
VBOTRH+
0V
Charge Condition
Enable Disabled Enabled Disabled Enabled
Figure 17. Temperature Monitoring
NOTE: The power-up default values are zero for these three thresholds. If the user opts not to use the temperature monitoring function during
the charge cycle, the TS pin of the IC must be tied to the GND to avoid an arror signal.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
27