English
Language : 

MSP430F20X3_14 Datasheet, PDF (25/94 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
www.ti.com
MSP430F20x3
MSP430F20x2
MSP430F20x1
SLAS491I – AUGUST 2005 – REVISED DECEMBER 2012
Outputs (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
TEST CONDITIONS
I(OHmax) = -1.5 mA (1)
I(OHmax) = -6 mA (2)
I(OHmax) = -1.5 mA(1)
I(OHmax) = -6 mA(2)
I(OLmax) = 1.5 mA(1)
I(OLmax) = 6 mA (2)
I(OLmax) = 1.5 mA(1)
I(OLmax) = 6 mA (2)
VCC
2.2 V
2.2 V
3V
3V
2.2 V
2.2 V
3V
3V
MIN
VCC - 0.25
VCC - 0.6
VCC - 0.25
VCC - 0.6
VSS
VSS
VSS
VSS
TYP
MAX
VCC
VCC
VCC
VCC
VSS + 0.25
VSS + 0.6
VSS + 0.25
VSS + 0.6
UNIT
V
V
(1) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±12 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
Output Frequency (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
fPx.y
Port output frequency
(with load)
P1.4/SMCLK, CL = 20 pF, RL = 1 kΩ(1) (2)
VCC
2.2 V
3V
MIN TYP
fPort°CLK
Clock output frequency P2.0/ACLK, P1.4/SMCLK, CL = 20 pF(2)
2.2 V
3V
MAX
10
12
12
16
UNIT
MHz
MHz
(1) A resistive divider with 2 × 0.5 kΩ between VCC and VSS is used as load. The output is connected to the center tap of the divider.
(2) The output voltage reaches at least 10% and 90% VCC at the specified toggle frequency.
Copyright © 2005–2012, Texas Instruments Incorporated
Submit Documentation Feedback
25