English
Language : 

AMC1304L05 Datasheet, PDF (25/39 Pages) Texas Instruments – High-Precision Reinforced Isolated Delta-Sigma Modulators
www.ti.com
AMC1304L05, AMC1304L25, AMC1304M05, AMC1304M25
SBAS655C – SEPTEMBER 2014 – REVISED SEPTEMBER 2015
Typical Applications (continued)
9.2.1.3 Application Curve
In motor control applications, a very fast response time for overcurrent detection is required. The time for fully
settling the filter in case of a step-signal at the input of the modulator depends on its order; that is, a sinc3 filter
requires three data updates for full settling (with fDATA = fCLK / OSR). Therefore, for overcurrent protection, filter
types other than sinc3 can be a better choice; an alternative is the sinc2 filter. Figure 52 compares the settling
times of different filter orders.
The delay time of the sinc filter with a continuous signal is half of its settling time.
16
14
12
10
8
6
4
sinc1
2
sinc2
sinc3
0
0 2 4 6 8 10 12 14 16 18 20
settling time (µs)
D054
Figure 52. Measured Effective Number of Bits versus Settling Time
Copyright © 2014–2015, Texas Instruments Incorporated
Submit Documentation Feedback
25
Product Folder Links: AMC1304L05 AMC1304L25 AMC1304M05 AMC1304M25