TLC32044MJB Datasheet, PDF (24/39 Pages) Texas Instruments – VOICE-BAND ANALOG INTERFACE CIRCUITS | |||
|
◁ |
TLC32044C, TLC32044E, TLC32044I, TLC32044M, TLC32045C, TLC32045I
VOICE-BAND ANALOG INTERFACE CIRCUITS
SLAS017F â MARCH 1988 â REVISED MAY 1995
delay distortion
bandpass filter transfer function, SCF fclock = 288 kHz IN + â INâ is a ± 3 V sinewaveâ (see Note 9)
PARAMETER
TEST CONDITIONS
FREQUENCY RANGE ADJUSTMENT ADDEND⡠MIN TYP§ MAX UNIT
f ⤠50 Hz
K1 Ã 0 dB
â33 â29 â25
f = 100 Hz
K1 Ã â 0.26 dB
â4 â2 â1
Filter gain,
TLC32044C,
TLC32044E,
TLC32044I
Input signal reference to 0 dB
f = 150 Hz to 3100 Hz
f = 3100 Hz to 3300 Hz
f = 3300 Hz to 3650 Hz
f = 3800 Hz
f = 4000 Hz
K1 Ã 0 dB
K1 Ã 0 dB
K1 Ã 0 dB
K1 Ã 2.3 dB
K1 Ã 2.7 dB
â 0.25
â 0.3
â 0.5
0 0.25
0 0.3
0 0.5
â3 â1
â17 â16
f ⥠4400 Hz
K1 Ã 3.2 dB
â 40
f ⥠5000 Hz
K1 Ã 0 dB
â 65
f ⤠50 Hz
K1 Ã 0 dB
â33 â29 â25
f = 100 Hz
K1 Ã â 0.26 dB
â4 â2 â1
f = 150 Hz to 3100 Hz
K1 Ã 0 dB
â 0.25
0 0.25
Filter gain,
TLC32044M
Input signal reference to 0 dB
f = 3100 Hz to 3300 Hz
f = 3300 Hz to 3500 Hz
f = 3800 Hz
K1 Ã 0 dB
K1 Ã 0 dB
K1 Ã 2.3 dB
â 0.3
â 0.5
0 0.3
0 0.5 dB
â3 â0.5
f = 4000 Hz
K1 Ã 2.7 dB
â17 â16
f ⥠4400 Hz
K1 Ã 3.2 dB
â 40
f ⥠5000 Hz
K1 Ã 0 dB
â 65
f ⤠50 Hz
K1 Ã 0 dB
â33 â29 â25
f = 100 Hz
K1 Ã â 0.26 dB
â4 â2 â1
f = 150 Hz to 3100 Hz
K1 Ã 0 dB
â 0.25
0 0.25
Filter gain,
TLC32045C,
TLC32045I
Input signal reference to 0 dB
f = 3100 Hz to 3300 Hz
f = 3300 Hz to 3650 Hz
f = 3800 Hz
K1 Ã 0 dB
K1 Ã 0 dB
K1 Ã 2.3 dB
â 0.3
â 0.5
0 0.3
0 0.5
â3 â1
f = 4000 Hz
K1 Ã 2.7 dB
â17 â16
f ⥠4400 Hz
K1 Ã 3.2 dB
â 40
f ⥠5000 Hz
K1 Ã 0 dB
â 65
â See filter curves in typical characteristics
â¡ The MIN, TYP, and MAX specifications are given for a 288-kHz SCF clock frequency. A slight error in the 288-kHz SCF may result from
inaccuracies in the MSTR CLK frequency, resulting from crystal frequency tolerances. If this frequency error is less than 0.25%, the
ADJUSTMENT ADDEND should be added to the MIN, TYP, and MAX specifications, where K1 = 100 â
[(SCF frequency â 288 kHz) / 288 kHz].
For errors greater than 0.25%, see Note 8.
§ All typical values are at TA = 25°C.
NOTE 9: The filter gain outside of the passband is measured with respect to the gain at 1 kHz. The filter gain within the passband is measured
with respect to the average gain within the passband. The passbands are 150 to 3600 Hz and 0 to 3600 Hz for the bandpass and
low-pass filters respectively. For switched-capacitor filter clocks at frequencies other than 288 kHz, the filter response is shifted by the
ratio of switched-capacitor filter clock frequency to 288 kHz.
24