SN54LVTH18514, SN54LVTH182514, SN74LVTH18514, SN74LVTH182514
3.3-V ABT SCAN TEST DEVICES
WITH 20-BIT UNIVERSAL BUS TRANSCEIVERS
SCBS670C – AUGUST 1996 – REVISED MARCH 1998
TCK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
TMS
TTDDOÎÎÎÎI ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
TAP
Controller
State
ÎÎÎÎ3-State (TDO) or Don’t Care (TDI)
Figure 13. Timing Example
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
Voltage range applied to any output in the high or power-off state, VO (see Note 1) . . . . . . . . . –0.5 V to 7 V
Current into any output in the low state, IO: SN54LVTH18514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
SN54LVTH182514 (A port or TDO) . . . . . . . . . . . . . . . . . . 96 mA
SN54LVTH182514 (B port) . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
SN74LVTH18514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
SN74LVTH182514 (A port or TDO) . . . . . . . . . . . . . . . . . 128 mA
SN74LVTH182514 (B port) . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
Current into any output in the high state, IO (see Note 2): SN54LVTH18514 . . . . . . . . . . . . . . . . . . . . . 48 mA
SN54LVTH182514 (A port or TDO) . . . . . . 48 mA
SN54LVTH182514 (B port) . . . . . . . . . . . . . 30 mA
SN74LVTH18514 . . . . . . . . . . . . . . . . . . . . . 64 mA
SN74LVTH182514 (A port or TDO) . . . . . . 64 mA
SN74LVTH182514 (B port) . . . . . . . . . . . . . 30 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Package thermal impedance, qJA (see Note 3): DGG package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings can be exceeded if the input and output clamp-current ratings are observed.
2. This current only flows when the output is in the high state and VO > VCC.
3. The package thermal impedance is calculated in accordance with JESD 51.
24