English
Language : 

MSP430F43X_14 Datasheet, PDF (22/70 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F43x
MIXED SIGNAL MICROCONTROLLER
SLAS713 -- JUNE 2010
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
Schmitt-trigger inputs -- Ports P1, P2, P3, P4, P5, and P6; RST/NMI; JTAG: TCK, TMS, TDI/TCLK, TDO/TDI
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
VIT+
VIT--
Vhys
Positive-going input threshold voltage
Negative-going input threshold voltage
Input voltage hysteresis (VIT+ -- VIT--)
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
1.1
1.55
V
1.5
1.98
0.4
0.9
V
0.9
1.3
0.3
1.1
V
0.5
1
inputs Px.x, TAx, TBx
PARAMETER
t(int)
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag, (see Note 1)
VCC
2.2 V
3V
MIN TYP MAX UNIT
62
ns
50
t(cap)
Timer_A, Timer_B capture
timing
TA0, TA1, TA2
TB0, TB1, TB2
2.2 V
62
ns
3V
50
f(TAext)
f(TBext)
Timer_A, Timer_B clock
frequency externally applied
to pin
TACLK, TBCLK, INCLK: t(H) = t(L)
2.2 V
3V
8
MHz
10
f(TAint)
f(TBint)
NOTES:
Timer_A, Timer_B clock
frequency
SMCLK or ACLK signal selected
2.2 V
3V
8
MHz
10
1. The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set even with trigger signals
shorter than t(int).
leakage current -- Ports P1, P2, P3, P4, P5, and P6 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Ilkg(Px.y)
Leakage
current
Port Px V(Px.y) (see Note 2)
VCC = 2.2 V/3 V
±50
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as input.
UNIT
nA
22