English
Language : 

SN74BCT29862B Datasheet, PDF (2/4 Pages) Texas Instruments – 10-BIT BUS TRANSCEIVERS WITH 3-STATE OUTPUTS
SN54BCT29862B, SN74BCT29862B
10ĆBIT BUS TRANSCEIVERS
WITH 3ĆSTATE OUTPUTS
SCBS014B − NOVEMBER 1988 − REVISED NOVEMBER 1993
logic symbol†
logic diagram (positive logic)
1
OEBA
13
OEAB
2
A1
3
A2
4
A3
5
A4
6
A5
7
A6
8
A7
9
A8
10
A9
11
A10
EN1
EN2
1
2
23
B1
22
B2
21
B3
20
B4
19
B5
18
B6
17
B7
16
B8
15
B9
14
B10
OEAB 13
A1 2
1 OEBA
23 B1
To Nine Other Channels
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
Pin numbers shown are for the DW, JT, NT, and W packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage (I/O ports) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 5.5 V
Input voltage (excluding I/O ports) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Voltage applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC
Input clamp current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −30 mA
Current into any output in the low state: SN54BCT29862B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA
SN74BCT29862B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 mA
Operating free-air temperature range: SN54BCT29862B . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 125°C
SN74BCT29862B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input negative voltage rating may be exceeded if the input clamp current rating is observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
SN54BCT29862B
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
− 12
24
− 55
125
SN74BCT29862B
MIN NOM MAX
4.5
5 5.5
2
0.8
− 18
− 24
48
0
70
UNIT
V
V
V
mA
mA
mA
°C
2