English
Language : 

OPA244 Datasheet, PDF (2/26 Pages) Burr-Brown (TI) – MicroPower, Single-Supply OPERATIONAL AMPLIFIERS MicroAmplifier ™ Series
SPECIFICATIONS: VS = +2.6V to +36V
Boldface limits apply over the specified temperature range, TA = –40°C to +85°C
At TA = +25°C, RL = 20kΩ connected to ground, unless otherwise noted.
PARAMETER
OFFSET VOLTAGE
Input Offset Voltage
TA = –40°C to 85°C
vs Temperature
vs Power Supply
TA = –40°C to 85°C
VOS
dVOS/dT
PSRR
INPUT BIAS CURRENT
Input Bias Current
IB
Input Offset Current
IOS
NOISE
Input Voltage Noise, f = 0.1kHz to 10kHz
Input Voltage Noise Density, f = 1kHz
en
Current Noise Density, f = 1kHz
in
INPUT VOLTAGE RANGE
Common-Mode Voltage Range
Common-Mode Rejection
TA = –40°C to 85°C
VCM
CMRR
INPUT IMPEDANCE
Differential
Common-Mode
OPEN-LOOP GAIN
Open-Loop Voltage Gain
TA = –40°C to 85°C
FREQUENCY RESPONSE
Gain-Bandwidth Product
Slew Rate
Settling Time 0.01%
Overload Recovery Time
AOL
GBW
SR
OUTPUT
Voltage Output, Positive
TA = –40°C to 85°C
Voltage Output, Negative
TA = –40°C to 85°C
Voltage Output, Positive
TA = –40°C to 85°C
Voltage Output, Negative
TA = –40°C to 85°C
Short-Circuit Current
Capacitive Load Drive
POWER SUPPLY
Specified Voltage Range
Minimum Operating Voltage
Quiescent Current
TA = –40°C to 85°C
TEMPERATURE RANGE
Specified Range
Operating Range
Storage Range
Thermal Resistance
SOT-23-5 Surface-Mount
SO-8 Surface-Mount
8-Pin DIP
VO
ISC
CLOAD
VS
IQ
θJA
NOTE: (1) VS = +15V.
CONDITION
VS = ±7.5V, VCM = 0
TA = –40°C to 85°C
VS = +2.6V to +36V
VS = +2.6V to +36V
VCM = VS /2
VCM = VS /2
VS = ±18V, VCM = –18V to +17.1V
VS = ±18V, VCM = –18V to +17.1V
VO = 0.5V to (V+) – 0.9
VO = 0.5V to (V+) – 0.9
G=1
10V Step
VIN • Gain = VS
AOL ≥ 80dB, RL = 20kΩ to VS/2
AOL ≥ 80dB, RL = 20kΩ to VS/2
AOL ≥ 80dB, RL = 20kΩ to VS/2
AOL ≥ 80dB, RL = 20kΩ to VS/2
AOL ≥ 80dB, RL = 20kΩ to Ground
AOL ≥ 80dB, RL = 20kΩ to Ground
AOL ≥ 80dB, RL = 20kΩ to Ground
AOL ≥ 80dB, RL = 20kΩ to Ground
TA = –40°C to 85°C
IO = 0
IO = 0
OPA244NA, PA, UA
MIN
TYP(1)
MAX
±0.7
±1.5
±2
±4
5
50
50
–10
–25
±1
±10
0.4
22
40
0
(V+) – 0.9
84
98
84
106 || 2
109 || 2
86
106
86
430
–0.1/+0.16
150
8
(V+) – 0.9 (V+) – 0.75
(V+) – 0.9 (V+) – 0.75
0.5
0.2
0.5
0.2
(V+) – 0.75
(V+) – 0.75
0.1
0.1
–25 / +12
See Typical Curve
+2.6
+36
+2.2
50
60
70
–40
85
–55
125
–65
150
200
150
100
UNITS
mV
mV
µV/°C
µV/V
µV/V
nA
nA
µVp-p
nV/√Hz
fA/√Hz
V
dB
dB
Ω || pF
Ω || pF
dB
dB
kHz
V/µs
µs
µs
V
V
V
V
V
V
V
V
mA
V
V
µA
µA
°C
°C
°C
°C/W
°C/W
°C/W
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant
any BURR-BROWN product for use in life support devices and/or systems.
®
OPA244, 2244, 4244
2