English
Language : 

74AC11174_10 Datasheet, PDF (2/8 Pages) Texas Instruments – HEX D-TYPE FLIP-FLOP WITH CLEAR
74AC11174
HEX DĆTYPE FLIPĆFLOP WITH CLEAR
ą
SCAS146 − MARCH 1990 − REVISED APRIL 1993
logic symbol†
20
CLR
11
CLK
19
1D
18
2D
17
3D
14
4D
13
5D
12
6D
R
C1
1D
1
1Q
2
2Q
3
3Q
8
4Q
9
5Q
10
6Q
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
logic diagram (positive logic)
20
CLR
11
CLK
19
1D
18
2D
17
3D
14
4D
13
5D
12
6D
1D
C1
R
1D
C1
R
1D
C1
R
1D
C1
R
1D
C1
R
1D
C1
R
ą
1
1Q
2
2Q
3
3Q
8
4Q
9
5Q
10 6Q
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)‡
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±150 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2−2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77001