www.ti.com
PARAMETER MEASUREMENT INFORMATION (continued)
HVDA551-Q1
HVDA553-Q1
SLLSEC4 – JUNE 2013
Figure 11. Receiver Voltage and Current Definitions
A. The input pulse is supplied by a generator having the following characteristics: PRR ≤ 125 kHz, 50% duty cycle,
tr ≤ 6 ns, tf ≤ 6 ns, ZO = 50 Ω.
B. CL includes instrumentation and fixture capacitance within ±20%.
C. C. For HVDA553 device versions VIO = VCC.
Figure 12. Receiver Test Circuit and Voltage Waveforms
VCANH
–11.1 V
12 V
–6 V
12 V
–11.5 V
12 V
–12 V
6V
Open
Table 7. Differential Input Voltage Threshold Test
INPUT
VCANL
–12 V
11.1 V
–12 V
6V
–12 V
11.5 V
–6 V
12 V
Open
|VID|
900 mV
900 mV
6V
6V
500 mV
500 mV
6V
6V
X
OUTPUT
R
L
L
L
VOL
L
H
H
H
VOH
H
H
Copyright © 2013, Texas Instruments Incorporated