English
Language : 

TPS73701_13 Datasheet, PDF (16/31 Pages) Texas Instruments – 1A Low-Dropout Regulator with Reverse Current Protection
TPS737xx
SBVS067O – JANUARY 2006 – REVISED JUNE 2012
ESTIMATING JUNCTION TEMPERATURE
Using the thermal metrics ΨJT and ΨJB, as shown in
the Thermal Information table, the junction
temperature can be estimated with corresponding
formulas (given in Equation 8). For backwards
compatibility, an older θJC,Top parameter is listed as
well.
YJT:
T
J
=
T
T
+
YJT
·
P
D
YJB:
T
J
=
T
B
+
YJB
·
P
D
(8)
Where PD is the power dissipation shown by
Equation 6, TT is the temperature at the center-top of
the IC package, and TB is the PCB temperature
measured 1mm away from the IC package on the
PCB surface (as Figure 35 shows).
NOTE: Both TT and TB can be measured on actual
application boards using a thermo-gun (an infrared
thermometer).
For more information about measuring TT and TB, see
the application note SBVA025, Using New Thermal
Metrics, available for download at www.ti.com.
By looking at Figure 34, the new thermal metrics (ΨJT
and ΨJB) have very little dependency on board size.
That is, using ΨJT or ΨJB with Equation 8 is a good
way to estimate TJ by simply measuring TT or TB,
regardless of the application board size.
TB on PCB
surface
1mm
TT on top
of IC
TB on PCB
surface
1mm
www.ti.com
35
30
DRV
25
DCQ YJB
DRB
20
15
DRV
DCQ YJT
10
DRB
5
0
0 1 2 3 4 5 6 7 8 9 10
Board Copper Area (in2)
Figure 34. ΨJT and ΨJB vs Board Size
For a more detailed discussion of why TI does not
recommend using θJC(top) to determine thermal
characteristics, refer to application report SBVA025,
Using New Thermal Metrics, available for download
at www.ti.com. For further information, refer to
application report SPRA953, IC Package Thermal
Metrics, also available on the TI website.
TT on top
of IC
TB
1mm X
TT
X
See note (1)
(a) Example DRB (SON) Package Measurement
(b) Example DRV (SON) Package Measurement
(c) Example DCQ (SOT-223) Package Measurement
(1) Power dissipation may limit operating range. Check Thermal Information table.
Figure 35. Measuring Points for TT and TB
16
Submit Documentation Feedback
Copyright © 2006–2012, Texas Instruments Incorporated