English
Language : 

TLE2021MDR Datasheet, PDF (16/77 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2021 electrical characteristics at specified free-air temperature, VCC = ± 15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2021I
MIN TYP MAX
TLE2021AI
MIN TYP MAX
TLE2021BI
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 500
850
80 200
500
40 100
μV
200
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
μV/°C
Input offset voltage long-term drift
(see Note 4)
VIC = 0, RS = 50 Ω
25°C
0.006
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.2
6
10
0.2
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
90
25
70
nA
90
−15 −15.3
−15 −15.3
−15 −15.3
25°C
to
to
to
to
to
to
VICR
Common-mode input voltage range
RS = 50 Ω
13.5
14
13.5
14
13.5
14
V
− 15
−15
−15
Full range
to
to
to
13.2
13.2
13.2
VOM +
VOM −
Maximum positive peak output
voltage swing
Maximum negative peak output
voltage swing
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.9
13.9
13.9
RL = 10 kΩ
25°C −13.7 −14.1
−13.7 −14.1
−13.7 −14.1
V
Full range −13.6
− 13.6
− 13.6
Large-signal differential
AVD
voltage amplification
VO = 10 V,
RL = 10 kΩ
25°C
1 6.5
Full range 0.75
1 6.5
0.75
1 6.5
0.75
V/μV
CMRR Common-mode rejection ratio
VIC = VICR min,
RS = 50 Ω
25°C
100 115
Full range
96
100 115
96
100 115
96
dB
kSVR
Supply-voltage rejection ratio
(ΔVCC /ΔVIO)
VCC ± = ± 2. 5 V
to ± 15 V
25°C
105 120
Full range 100
105 120
100
105 120
100
dB
ICC
ΔICC
Supply current
Supply-current change over
operating temperature range
VO = 0 V, No load
25°C
Full range
Full range
240 350
350
7
240 350
350
7
240 350
μA
350
7
μA
† Full range is − 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.