ISO35T_15 Datasheet, PDF (15/31 Pages) Texas Instruments – Isolated 3.3V RS-485 Transceiver With Integrated Transformer Driver
www.ti.com
8.3.2 IEC 60664-1 Ratings Table
ISO35T
SLLSE26D – NOVEMBER 2010 – REVISED OCTOBER 2015
PARAMETER
Material group
Overvoltage category / Installation
classification for basic insulation
TEST CONDITIONS
Rated mains voltage ≤ 150 VRMS
Rated mains voltage ≤ 300 VRMS
SPECIFICATION
II
I-IV
I-III
8.3.3 DIN V VDE V 0884-10 Insulation Characteristics(1)
over recommended operating conditions (unless otherwise noted)
VIORM
PARAMETER
Maximum working isolation voltage
VPR
Input to output test voltage
VIOTM Maximum transient isolation voltage
VIOSM Maximum surge isolation voltage
RS
Isolation resistance
Pollution degree
(1) Climatic Classification 40/125/21
TEST CONDITIONS
Method b1, VPR = VIORM × 1.875,
100% Production test with t = 1 s,
Partial discharge < 5 pC
Method a, After environmental tests subgroup 1,
VPR = VIORM × 1.6, t = 10 s,
Partial discharge < 5pC
After Input/Output Safety Test Subgroup 2/3,
VPR = VIORM x 1.2, t = 10 s,
Partial discharge < 5 pC
t = 60 s (Qualification)
t = 1 s (100% Production)
Tested per IEC 60065, 1.2/50 µs waveform,
VTEST = 1.3 x VIOSM = 4000 VPK(Qualification Test)
VIO = 500 V at TS = 150 °C
SPECIFICATION
566
1062
906
680
4242
3077
> 109
2
UNIT
VPK
VPK
VPK
VPK
Ω
8.3.4 Regulatory Information
VDE
CSA
Certified according to DIN V VDE V 0884-
10(VDE V 0884-10):2006-12 and DIN EN
61010-1 (VDE 0411-1)
Approved according to CSA Component
Acceptance Notice 5A, IEC 60959-1 and IEC
61010-1
Basic Insulation
Maximum Transient Isolation Voltage, 4242
VPK
Maximum Surge Isolation Voltage, 3077 VPK
Maximum Working Isolation Voltage, 566
VPK
Certificate Number: 40016131
3000 VRMS Isolation Rating;
Reinforced insulation per CSA 61010-1-04 and
IEC 61010-1 2nd Ed. 150 VRMS working
voltage;
Basic insulation per CSA 61010-1-04 and IEC
61010-1 2nd Ed. 600 VRMS working voltage;
Basic insulation per CSA 60950-1-07 and IEC
60950-1 2nd Ed. 760 VRMS working voltage
Master Contract Number: 220991
UL
Approved under UL 1577 Component
Recognition Program
Single Protection, 2500 VRMS(1)
File Number: E181974
(1) Production tested ≥ 3000 VRMS for 1 second in accordance with UL 1577.
8.3.5 Safety Limiting Values
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output circuitry.
A failure of the IO can allow low resistance to ground or the supply. Without current limiting, sufficient power is
dissipated to overheat the die and damage the isolation barrier—potentially leading to secondary system failures.
PARAMETER
IS Safety input, output, or supply current
TS Maximum safety temperature
TEST CONDITIONS
DW-16 θJA = 80.5°C/W, VI = 3.6V, TJ = 170°C, TA = 25°C
MIN TYP MAX UNIT
500 mA
150 °C
Copyright © 2010–2015, Texas Instruments Incorporated
Product Folder Links: ISO35T
Submit Documentation Feedback
15