Figure 26. INA200 Basic Connections
7.3.2 Selecting RS
The value chosen for the shunt resistor, RS, depends on the application and is a compromise between small-
signal accuracy and maximum permissible voltage loss in the measurement line. High values of RS provide better
accuracy at lower currents by minimizing the effects of offset, while low values of RS minimize voltage loss in the
supply line. For most applications, best performance is attained with an RS value that provides a full-scale shunt
voltage range of 50 mV to 100 mV. Maximum input voltage for accurate measurements is 500 mV, but output
voltage is limited by supply.
7.3.3 Comparator
The INA200, INA201, and INA202 devices incorporate an open-drain comparator. This comparator typically has
2 mV of offset and a 1.3-μs (typical) response time. The output of the comparator latches and is reset through
the RESET pin; see Figure 28.