Electrical Characteristics (continued)
Symbol
Parameter
Conditions
Min Typ Max Units
Power Dissipation
ICC0
Power down current (all
channels down)
ICC1
Power up active current
(all channel active)
Measured after having first
achieved power-up state.
MCLK=2.048MHz
No load, MCLK=2.048MHz
0.9
1.5
mA
35
50
mA
Amplitude Response
Absolute Levels
tmax
Virtual decision value
defined per ITU G.711
GXA
Transmit gain, absolute
GXAT/V
GXR
Cumulative Transmit
gain Variation with sup-
plies and temperature
ranges
Transmit gain, relative
to GXA
GXAL
Transmit gain variation
with level
GRA
Receive gain, absolute
GRAT/V
GRR
Cumulative Receive gain
Variation with supplies
and temperature ranges
Receive gain, relative to
GRA
Nominal 0dBm0 level is 0dBm at
the analog inputs/outputs
Max overload level
3.17dBm0 (µ-law)
3.14dBm0 (A-law)
TA=25oC, VCC=5V,
Input at VXI=0dBm0 at
1015.625Hz
TA=0oC to 70oC, VCC=5V±5%,
TA=-40oC to +85oC, VCC=5V±5%
Input at GXO=0dBm0 at
1015.625Hz
f=16Hz
f=50Hz
f=60Hz
f=200Hz
f=300-3000Hz
f=3300Hz
f=3400Hz
f=4000Hz
f=4.6KHz and up (Note 2),
measure response from 0 to
4000Hz
Sinusoidal test method, refer-
ence level = -10dBm0 at VXI
GXO=-40dBm0 to +3dBm0
GXO=-50dBm0 to -40dBm0
GXO=-55dBm0 to -50dBm0
TA=25oC, VCC=5V±5%
Input PCM level at DR=0dBm0 at
1015.625Hz
TA=0oC to 70oC, VCC=5V±5%,
TA=-40oC to 85oC, VCC=5V±5%,
Input PCM level at DR=0dBm0 at
1015.625Hz
f=0-3000Hz
f=3300Hz
f=3400Hz
f=4000Hz
-0.15
-0.2
-0.3
-1.8
-0.15
-0.35
-0.7
-0.2
-0.4
-1.0
-0.15
-0.2
-0.3
-0.15
-0.35
-0.7
0.7746
Vrms
1.116
1.112
0.15
Vrms
Vrms
dB
0.2
dB
dB
0.3
-35
dB
-30
dB
-30
dB
0
dB
0.15 dB
0.15 dB
0
dB
-14
dB
-32
dB
dB
0.2
dB
0.4
dB
1.0
dB
0.15 dB
0.2
dB
0.3
0.15 dB
0.15 dB
0
dB
-14
dB
12