English
Language : 

TLE206X_16 Datasheet, PDF (12/82 Pages) Texas Instruments – EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE POWER OPERATIONAL AMPLIFIERS
TLE206x, TLE206xA, TLE206xB
ą
EXCALIBUR JFETĆINPUT HIGHĆOUTPUTĆDRIVE
µPOWER OPERATIONAL AMPLIFIERS
SLOS193B − FEBRUARY 1997 − REVISED MAY 2004
TLE2061I electrical characteristics at specified free-air temperature, VCC± = ±15 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2061I, TLE2061AI
TLE2061BI
MIN
TYP
MAX
UNIT
TLE2061I
25°C
Full range
0.6
3
4.3
VIO
Input offset voltage
TLE2061AI
25°C
Full range
0.5
1.5
mV
2.9
αVIO
TLE2061BI
Temperature coefficient of input offset
voltage
VIC = 0,
RS = 50 Ω
25°C
Full range
Full range
0.3
0.5
1.3
6
µV/°C
Input offset voltage long-term drift
(see Note 4)
25°C
0.04
µV/mo
IIO
Input offset current
25°C
Full range
2
pA
3 nA
IIB
Input bias current
25°C
Full range
4
pA
5 nA
VICR Common-mode input voltage range
25°C
−11 to 13 −12 to 16
V
Full range −11 to 13
V
25°C
13.2
13.7
RL = 10 kΩ
Full range
13
VOM + Maximum positive peak output voltage swing
V
25°C
12.5
13.2
RL = 600 Ω
Full range
12
25°C
−13.2
− 13.7
VOM −
Maximum negative peak output voltage
swing
RL = 10 kΩ
Full range
− 13
25°C
− 12.5
− 13
V
RL = 600 Ω
Full range
− 12
VO = ± 10 V,
RL = 10 kΩ
25°C
30
230
Full range
20
AVD
Large-signal differential voltage amplification
VO = 0 to 8 V,
RL = 600 Ω
25°C
25
100
Full range
10
V/mV
ri
Input resistance
ci
Input capacitance
zo
Open-loop output impedance
CMRR Common-mode rejection ratio
VO = 0 to − 8 V,
25°C
3
25
RL = 600 Ω
Full range
01
25°C
1012
Ω
25°C
4
pF
IO = 0
25°C
280
Ω
VIC = VICRmin,
25°C
72
90
RS = 50 Ω
Full range
65
dB
kSVR
Supply-voltage rejection ratio (∆VCC± /∆VIO)
VCC± = ± 5 V to ± 15 V, 25°C
RS = 50 Ω
Full range
75
65
93
dB
ICC
∆ICC
Supply current
Supply-current change over operating
temperature range
VO = 0,
No load
25°C
Full range
Full range
290
350
µA
375
34
µA
† Full range is − 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
12