Verifying Results
www.ti.com
5 Verifying Results
Making measurements on the LOG114EVM is fast and easy. Connect a digital voltmeter or oscilloscope to
the terminal of interest and record the results. Included with the graph of measured results is a table of
results for common values of input currents. In Figure 13, two curves are shown. Both curves use a
resistor input and VOUT is recorded as a function of input current. The compensated (red) curve connects
the resistor as shown in Figure 11 and uses the high-current linearity correction circuitry. The
uncompensated curve (blue) uses the resistor connected to I1 and VREF as shown in Figure 10.
3
Uncompensated Output
Compensated Output
2.5
2
1.5
1
10n 100n
1m
10m 100m
1m
10m
Input Current (A)
Figure 13. LOG114EVM Measured Results
Table 1 lists several typical results obtained with various input voltages.
Input
10 nA
100 nA
1 μA
10 μA
100 μA
1 mA
10 mA
Table 1. LOG114EVM Typical Results
Uncompensated
VLOGOUT (V)
1.36
VOUT (V)
1.15
1.74
1.38
2.11
1.60
2.49
1.83
2.87
2.06
3.29
2.31
4.11
2.82
Compensated
VLOGOUT (V)
1.36
VOUT (V)
1.15
1.74
1.38
2.11
1.60
2.49
1.83
2.87
2.06
3.29
2.30
4.11
2.67