English
Language : 

TLE2037IDR Datasheet, PDF (10/46 Pages) Texas Instruments – EXCALIBUR LOW-NOISE HIGH-SPEED PRECISION OPERATIONAL AMPLIFIERS
TLE2027, TLE2037, TLE2027A, TLE2037A, TLE2027Y, TLE2037Y
EXCALIBUR LOW-NOISE HIGH-SPEED
PRECISION OPERATIONAL AMPLIFIERS
SLOS192C − FEBRUARY 1997 − REVISED APRIL 2010
TLE20x7M electrical characteristics at specified free-air temperature, VCC± = ±15 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TLE20x7M
TLE20x7AM
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
20 100
200
10
25
μV
105
αVIO
Temperature coefficient of
input offset voltage
Full range
0.4
1*
0.2
1* μV/°C
Input offset voltage
long-term drift (see Note 4) VIC = 0,
RS = 50 Ω
25°C
0.006
1*
0.006
1* μV/mo
IIO
Input offset current
25°C
Full range
6
90
150
6
90
nA
150
IIB
Input bias current
25°C
Full range
15
90
150
15
90
150 nA
VICR
Common-mode input
voltage range
RS = 50 Ω
−11 −13
−11 −13
25°C
to
to
to
to
11
13
11
13
V
− 10.3
− 10.4
Full range
to
to
10.3
10.4
VOM +
Maximum positive peak
output voltage swing
RL = 600 Ω
RL = 2 kΩ
25°C
10.5 12.9
10.5 12.9
Full range
25°C
10
12 13.2
10
12 13.2
V
Full range
11
11
Maximum negative peak
VOM − output voltage swing
RL = 600 Ω
RL = 2 kΩ
25°C
−10.5 −13
−10.5 −13
Full range −10
− 10
25°C
− 12 −13.5
− 12 −13.5
V
Full range − 11
− 11
VO = ± 11 V, RL = 2 kΩ
25°C
5
45
VO = ± 10 V, RL = 2 kΩ
Full range
2.5
Large-signal differential
AVD
voltage amplification
VO = ± 10 V, RL = 1 kΩ
25°C
Full range
3.5
1.8
38
10
45
3.5
8
38
2.2
V/μV
Ci
Input capacitance
zo
Open-loop output
impedance
VO = ± 10 V, RL = 600 Ω
IO = 0
25°C
25°C
25°C
2
19
8
50
5
19
8
pF
50
Ω
Common-mode rejection
CMRR ratio
VIC = VICRmin,
RS = 50 Ω
25°C
Full range
100 131
96
117 131
113
dB
kSVR
Supply-voltage rejection
ratio (ΔVCC ± /ΔVIO)
ICC
Supply current
VCC ± = ± 4 V to ± 18 V,
RS = 50 Ω
VCC ± = ± 4 V to ± 18 V,
RS = 50 Ω
VO = 0, No load
25°C
Full range
25°C
Full range
94 144
110 144
dB
90
105
3.8 5.3
5.6
3.8 5.3
mA
5.6
* On products compliant to MIL-PRF-38535, this parameter is not production tested.
† Full range is − 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10