English
Language : 

CC2541-Q1 Datasheet, PDF (10/35 Pages) Texas Instruments – SimpleLink Bluetooth Low Energy Wireless MCU for Automotive
CC2541-Q1
SWRS128 – JUNE 2014
www.ti.com
4.7 RF Receive Section
Measured on Texas Instruments CC2541-Q1 EM reference design with TA = 25°C, VDD = 3 V, fc = 2440 MHz
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
1 Mbps, GFSK, 250-kHz Deviation, Bluetooth low energy Mode, 0.1% BER
Receiver sensitivity(1)(2)
Saturation (2)
Co-channel rejection(2)
High-gain mode
Standard mode
BER < 0.1%
Wanted signal –67 dBm
–94
dBm
–88
5
dBm
–6
dB
±1 MHz offset, 0.1% BER, wanted signal –67 dBm
–2
In-band blocking rejection(2) ±2 MHz offset, 0.1% BER, wanted signal –67 dBm
±3 MHz offset, 0.1% BER, wanted signal –67 dBm
26
dB
34
>6 MHz offset, 0.1% BER, wanted signal –67 dBm
33
Out-of-band blocking
rejection (2)
Intermodulation (2)
Minimum interferer level < 2 GHz (Wanted signal –67 dBm)
Minimum interferer level [2 GHz, 3 GHz] (Wanted signal –67 dBm)
Minimum interferer level > 3 GHz (Wanted signal –67 dBm)
Minimum interferer level
–21
–27
dBm
–8
–36
dBm
Frequency error tolerance(3)
Including both initial tolerance and drift. Sensitivity better than -67dBm,
250 byte payload. BER 0.1%
–250
250 kHz
Symbol rate error
tolerance (4)
Maximum packet length. Sensitivity better than –67 dBm, 250 byte
payload. BER 0.1%
–80
80 ppm
ALL RATES/FORMATS
Spurious emission in RX.
Conducted measurement
f < 1 GHz
–67
dBm
Spurious emission in RX.
Conducted measurement
f > 1 GHz
–57
dBm
(1) The receiver sensitivity setting is programmable using a TI BLE stack vendor-specific API command. The default value is standard
mode.
(2) Results based on standard-gain mode.
(3) Difference between center frequency of the received RF signal and local oscillator frequency
(4) Difference between incoming symbol rate and the internally generated symbol rate
10
Specifications
Submit Documentation Feedback
Product Folder Links: CC2541-Q1