English
Language : 

XTR300 Datasheet, PDF (1/38 Pages) Burr-Brown (TI) – Industrial Analog Current/Voltage OUTPUT DRIVER
XTR300
XTR300
www.ti.com
SBOS336C – JUNE 2005 – REVISED JUNE 2011
Industrial Analog Current/Voltage
OUTPUT DRIVER
Check for Samples: XTR300
FEATURES
1
•2 USER-SELECTABLE: Voltage or Current
Output
• +40V SUPPLY VOLTAGE
• VOUT: ±10V (up to ±17.5V at ±20V supply)
• IOUT: ±20mA (linear up to ±24mA)
• SHORT- OR OPEN-CIRCUIT FAULT
INDICATOR PIN
• NO CURRENT SHUNT REQUIRED
• OUTPUT DISABLE FOR SINGLE INPUT MODE
• THERMAL PROTECTION
• OVERCURRENT PROTECTION
• SEPARATE DRIVER AND RECEIVER
CHANNELS
• DESIGNED FOR TESTABILITY
CC
Input Signal
(Optional)
ROS
VREF
XTR300 V+
V-
IMON
Current Copy
RIMON
1kW
VIN
SET
ICOPY
IDRV
OPA
DRV
RSET
GND1
RIA
1kW
GND3
IIA
IAOUT
OD
M1 Digital
M2 Control
IAIN+
RG1
IA
RG2
IAIN-
Error
Flags
EFCM
EFLD
EFOT
DGND
RGAIN Load
GND2
Figure 1. XTR300 Basic Diagram
APPLICATIONS
• PLC OUTPUT PROGRAMMABLE DRIVER
• INDUSTRIAL CROSS-CONNECTORS
• INDUSTRIAL HIGH-VOLTAGE I/O
• 3-WIRE-SENSOR CURRENT OR VOLTAGE
OUTPUT
• ±10V 2- AND 4-WIRE VOLTAGE OUTPUT
U.S. Patent Nos. 7,427,898, 7,425,848, and
7,449,873
Other Patents Pending
space
space
DESCRIPTION
The XTR300 is a complete output driver for industrial
and process control applications. The output can be
configured as current or voltage by the digital I/V
select pin. No external shunt resistor is required. Only
external gain-setting resistors and a loop
compensation capacitor are required.
The separate driver and receiver channels provide
flexibility. The Instrumentation Amplifier (IA) can be
used for remote voltage sense or as a high-voltage,
high-impedance measurement channel. In voltage
output mode, a copy of the output current is provided,
allowing calculation of load resistance.
The digital output selection capability, together with
the error flags and monitor pins, make remote
configuration and troubleshooting possible. Fault
conditions on the output and on the IA input as well
as over-temperature conditions are indicated by the
error flags. The monitoring pins provide continuous
feedback about load power or impedance. For
additional protection, the maximum output current is
limited and thermal protection is provided.
The XTR300 is specified over the −40°C to +85°C
industrial temperature range and for supply voltages
up to 40V.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
All trademarks are the property of their respective owners.
2
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.