English
Language : 

TPIC2406 Datasheet, PDF (1/13 Pages) Texas Instruments – INTELLIGENT-POWER QUAD MOSFET LATCH
ą
TPIC2406
INTELLIGENTĆPOWER QUAD MOSFET LATCH
ą
SLIS012 − D3378, FEBRUARY 1990
• Output Voltage up to 60 V
• Four Output Channels of 700-mA Nominal
Current Per Channel
• Pulsed Current . . . 3 A Per Channel
• Low rDS(on) . . . 0.5 Ω Typ
• Avalanche Energy . . . 50 mJ
• Thermal Shutdown Protection With Fault
(Overtemperature) Output
• NE Package Designed for Heat Sinking
• Integral Output Clamp Diodes
• Input Transparent Latches for Data Storage
• Asynchronous Clear to Turn off All Outputs
• Output Parallel Capability for Increased
Current Drive up to 12-A Total Pulsed Load
Current
description
The TPIC2406 is a monolithic, high-voltage,
high-current, quadruple power driver designed for
use in systems that require high load power. The
device contains built-in high-speed output clamp
diodes for inductive transient protection. Power
driver applications include lamps, relays,
solenoids, and dc stepping motors.
NE PACKAGE
(TOP VIEW)
1,4 CLAMP 1
ENBL 2
1 IN 3
1 DRAIN 4
HEAT SINK 5
AND GND 6
2 DRAIN 7
2 IN 8
VCC 9
F 10
20 CLR
19 LGND
18 4 IN
17 4 DRAIN
16 HEAT SINK
15 AND GND
14 3 DRAIN
13 3 IN
12 VDD
11 2,3 CLAMP
FUNCTION TABLE
(each channel)
FUNCTION
Normal
Operation
Thermal
Shutdown
H = high-level,
INPUTS
ENBL CLR IN
X LX
L HL
L HH
H HX
OUTPUT
Y
H
H
L
Q0
X XX
H
L = low-level, X = irrelevant
FAULT
F
H
H
H
H
L
The device features four inverting open-drain outputs, each controlled by an input storage latch with common
clear and enable controls. All inputs accept standard TTL- and CMOS-logic levels. The CLR function is
asynchronous and turns all four outputs off regardless of data inputs. Taking ENBL low puts the input latch into
a transparent mode, allowing the data inputs to affect the output. In this state, all four outputs are held off while
CLR is low, but return to the stages on the data inputs when CLR goes high. When ENBL is taken high, the latch
is put into a storage mode and the last state of the data inputs is held in the latches. If CLR is taken low, the data
in the latches is cleared and all outputs are turned off. If CLR is taken high again, ENBL must be cycled low to
read new data into the latch.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
• POST OFFICE BOX 1443 HOUSTON, TEXAS 77001
Copyright  1990, Texas Instruments Incorporated
2−1