English
Language : 

TMP116 Datasheet, PDF (1/46 Pages) Texas Instruments – High-Accuracy, Low-Power, Digital Temperature Sensor With SMBus- and I2C-Compatible Interface
Product
Folder
Order
Now
Technical
Documents
Tools &
Software
Support &
Community
TMP116, TMP116N
SBOS740 – MAY 2017
TMP116x High-Accuracy, Low-Power, Digital Temperature Sensor
With SMBus- and I2C-Compatible Interface
1 Features
•1 TMP116 Accuracy Without Calibration:
– ±0.2°C (max) From –10°C to +85°C
– ±0.25°C (max) From –40°C to +105°C
– ±0.3°C (max) From +105°C to +125°C
• TMP116N Accuracy Without Calibration:
– ±0.3°C (max) From –25°C to +85°C
– ±0.4°C (max) From –40°C to +125°C
• Low Quiescent Current:
– 3.5-μA, 1-Hz Conversion Cycle
– 250-nA Shutdown Current
• Supply Range: 1.9 V to 5.5 V
• Resolution: 16 Bits at 0.0078°C (1 LSB)
• Programmable Temperature Alert Limits
• General-Purpose EEPROM: 64 Bits
• NIST Traceability
• SMBus™, I2C Interface Compatibility
2 Applications
• Environmental Monitoring and Thermostats
• Wearables
• Asset Tracking and Cold Chain
• Gas Meters and Heat Meters
• Test and Measurement
• RTDs Replacement: PT100, PT500, PT1000
• Cold-Junction Compensation of Thermocouples
SPACE
Simplified Schematic
1.9-V to 5.5-V
Supply Voltage
Two-Wire
Host Controller
5k
Pullup
Resistors
1
SCL
TMP116
6
SDA
2
GND
5
V+
3
ALERT
4
ADD0
0.1-µF
Supply Bypass
Capacitor
Copyright © 2017, Texas Instruments Incorporated
3 Description
The TMP116 (TMP116, TMP116N) is a family of low-
power, high-precision temperature sensors with
integrated EEPROM memory. The TMP116 provides
a 16-bit temperature result with a resolution of
0.0078°C and an accuracy of up to ±0.2°C with no
calibration. The TMP116 is I2C- and SMBus-interface
compatible, has programmable alert functionality, and
can support up to four devices on a single bus.
The TMP116 consumes minimal current that, in
addition to providing power savings, minimizes self-
heating and improves measurement accuracy. The
TMP116 operates from 1.9 V to 5.5 V and typically
consumes 3.5 µA.
Across the device operating temperature range of
–55°C to +125°C, the TMP116 exceeds the accuracy
of a class A RTD, while consuming less than one fifth
of the typical excitation current for a PT100 RTD. The
TMP116 is easier to use than RTDs, eliminating the
need for calibration, external circuitry, matched
traces, and Kelvin connections.
The TMP116 units are 100% tested on a production
setup that is NIST traceable and verified with
equipment that is calibrated to ISO/IEC 17025
accredited standards.
Device Information(1)
PART NUMBER
PACKAGE
BODY SIZE (NOM)
TMP116
WSON (6)
2.00 mm x 2.00 mm
(1) For all available packages, see the package option addendum
at the end of the datasheet.
0.5
0.4
0.3
0.2
0.1
0
-0.1
-0.2
-0.3
-0.4
-0.5
-55
Temperature Accuracy
Average
116N Max Limit
116 Max Limit
116 Min Limit
116N Min Limit
-25
5
35
65
95
Temperature (°C)
Avg ±3σ
125 150
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.