English
Language : 

SN75182DR Datasheet, PDF (1/24 Pages) Texas Instruments – DUAL DIFFERENTIAL LINE RECEIVERS
SN55182, SN75182
DUAL DIFFERENTIAL LINE RECEIVERS
SLLS092D – OCTOBER 1972 – REVISED APRIL 1998
D Single 5-V Supply
D Differential Line Operation
D Dual Channels
D TTL Compatibility
D ±15-V Common-Mode Input Voltage Range
D ±15-V Differential Input Voltage Range
D Individual Channel Strobes
D Built-In Optional Line-Termination Resistor
D Individual Frequency Response Controls
D Designed for Use With Dual Differential
Drivers SN55183 and SN75183
D Designed to Be Interchangeable With
National Semiconductor DS7820A and
DS8820A
SN55182 . . . J OR W PACKAGE
SN75182 . . . N PACKAGE
(TOP VIEW)
1IN– 1
1RT 2
1IN+ 3
1STRB 4
1RTC 5
1OUT 6
GND 7
14 VCC
13 2IN–
12 2RT
11 2IN+
10 2STRB
9 2RTC
8 2OUT
SN55182 . . . FK PACKAGE
(TOP VIEW)
description
The SN55182 and SN75182 dual differential line
receivers are designed to sense small differential
signals in the presence of large common-mode
noise. These devices give TTL-compatible output
signals as a function of the polarity of the
differential input voltage. The frequency response
of each channel can be easily controlled by a
single external capacitor to provide immunity to
differential noise spikes. The output goes to a high
level when the inputs are open circuited. A strobe
input (STRB) is provided that, when in the low
level, disables the receiver and forces the output
to a high level.
1IN+
NC
1STRB
NC
1RTC
3 2 1 20 19
4
18
5
17
6
16
7
15
8
14
9 10 11 12 13
2RT
NC
2IN+
NC
2STRB
NC – No internal connection
THE SN55182 IS NOT RECOMMENDED
FOR NEW DESIGNS
The receiver is of monolithic single-chip construction, and both halves of the dual circuits use common
power-supply and ground terminals.
The SN55182 is characterized for operation over the full military temperature range of –55°C to 125°C. The
SN75182 is characterized for operation from 0°C to 70°C.
FUNCTION TABLE
INPUTS
STRB VID
L
X
OUTPUT
OUT
H
H
H
H
H
L
L
H = VI ≥ VIH min or VID more
positive than VTH max
L = VI ≤ VIL max or VID more
negative than VTL max
X = irrelevant
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Copyright © 1998, Texas Instruments Incorporated
1