English
Language : 

SN65LVDS86A-Q1 Datasheet, PDF (1/17 Pages) Texas Instruments – FlatLink™ RECEIVER
SN65LVDS86A-Q1
www.ti.com
SLLS768A – AUGUST 2006 – REVISED JANUARY 2012
FlatLink™ RECEIVER
Check for Samples: SN65LVDS86A-Q1
FEATURES
1
•2 3:21 Data Channel Expansion at up to
178.5 Mbytes/s Throughput
• Suited for SVGA, XGA, or SXGA Display Data
Transmission From Controller to Display With
Very Low EMI
• Three Data Channels and Clock Low-Voltage
Differential Channels In and 21 Data and Clock
Low-Voltage TTL Channels Out
• Operates From a Single 3.3-V Supply
• Tolerates 4-kV Human-Body Model (HBM) ESD
• Packaged in Thin Shrink Small-Outline
Package (TSSOP) With 20-Mil Terminal Pitch
• Consumes Less Than 1 mW When Disabled
• Wide Phase-Lock Input Frequency Range
31 MHz to 68 MHz
• No External Components Required for PLL
• Inputs Meet or Exceed the Standard
Requirements of ANSI EIA/TIA-644 Standard
• Improved Replacement for the SN75LVDS86
and NSC DS90C364
• Improved Jitter Tolerance
• Qualified for Automotive Applications
DGG PACKAGE
(TOP VIEW)
D17 1
D18 2
GND 3
D19 4
D20 5
NC 6
LVDSGND 7
A0M 8
A0P 9
A1M 10
A1P 11
LVDSVCC 12
LVDSGND 13
A2M 14
A2P 15
CLKINM 16
CLKINP 17
LVDSGND 18
PLLGND 19
PLLVCC 20
PLLGND 21
SHTDN 22
CLKOUT 23
D0 24
48 VCC
47 D16
46 D15
45 D14
44 GND
43 D13
42 VCC
41 D12
40 D11
39 D10
38 GND
37 D9
36 VCC
35 D8
34 D7
33 D6
32 GND
31 D5
30 D4
29 D3
28 VCC
27 D2
26 D1
25 GND
NC − Not connected
DESCRIPTION
The SN65LVDS86A FlatLink™ receiver contains three serial-in 7-bit parallel-out shift registers and four
low-voltage differential signaling (LVDS) line receivers in a single integrated circuit. These functions allow receipt
of synchronous data from a compatible transmitter, such as the SN75LVDS81, '83, '84, or '85, over four
balanced-pair conductors and expansion to 21 bits of single-ended low-voltage LVTTL synchronous data at a
lower transfer rate.
When receiving, the high-speed LVDS data is received and loaded into registers at seven times the LVDS input
clock (CLKIN) rate. The data is then unloaded to a 21-bit wide LVTTL parallel bus at the CLKIN rate. The
SN65LVDS86A presents valid data on the falling edge of the output clock (CLKOUT).
The SN65LVDS86A requires only four line-termination resistors for the differential inputs and little or no control.
The data bus appears the same at the input to the transmitter and output of the receiver with the data
transmission transparent to the user(s). The only user intervention is the possible use of the shutdown/clear
(SHTDN) active-low input to inhibit the clock and shut off the LVDS receivers for lower power consumption. A low
level on this signal clears all internal registers to a low level.
The SN65LVDS86A is characterized for operation over the full automotive temperature range of –40°C to 125°C.
1
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas
Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
FlatLink is a trademark of Texas Instruments.
2
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2006–2012, Texas Instruments Incorporated