SN65HVD265, SN65HVD266, SN65HVD267
SLLSEI3A – SEPTEMBER 2013 – REVISED NOVEMBER 2015
SN65HVD26x Turbo CAN Transceivers for CAN FD (Flexible Data Rate) and Redundancy
1 Features
•1 Meets the Requirements of ISO11898-2
• Turbo CAN:
– Specified for 2-Mbps CAN FD (CAN with
Flexible Data Rate)
– Short and Symmetrical Propagation Delay
Times and Fast Loop Times for Enhanced
Timing Margin
– Higher Data Rates in CAN Networks
• I/O Voltage Range Supports 3.3-V and 5-V MCUs
• Ideal Passive Behavior When Unpowered
– Bus and Logic Terminals are High Impedance
(no load)
– Power-Up/Down With Glitch Free Operation
On Bus
• Protection Features
– HBM ESD Protection Exceeds ±12 kV
– Bus Fault Protection –27 V to 40 V
– Undervoltage Protection on Supply Terminals
– Driver Dominant Time Out (TXD DTO)
– SN65HVD267: Receiver Dominant Time Out
(RXD DTO)
– SN65HVD267: FAULT Output Terminal
– Thermal Shutdown Protection
• Characterized for –40°C to 125°C Operation
2 Applications
• 2-Mbps Operation in CAN with Flexible Data Rate
Networks
• 1-Mbps Operation in Highly Loaded CAN
Networks Down to 10-kbps Networks Using TXD
DTO
• Industrial Automation, Control, Sensors and Drive
Systems
• Building, Security and Climate Control Automation
• Telecom Base Station Status and Control
• SN65HVD267: Functional Safety With Redundant
and Multi-topology CAN networks
• CAN Bus Standards Such as CANopen,
DeviceNet, NMEA2000, ARNIC825, ISO11783,
CANaerospace
3 Description
This CAN transceiver meets the ISO1189-2 High
Speed CAN (Controller Area Network) physical layer
standard. It is designed for data rates in excess of 2
Mpbs (megabits per second) for CAN FD (CAN with
flexible data rate), greater than 1 Mbps for CAN in
short networks, and enhanced timing margin and
higher data rates in long and highly-loaded networks.
The device provides many protection features to
enhance device and CAN-network robustness. The
SN65HVD267 adds additional features, allowing easy
design of redundant and multi-topology networks with
fault indication for higher levels of safety in the CAN
system.
Device Information (1)
PART NUMBER
PACKAGE
BODY SIZE
SN65HVD26xD
SOIC (8)
4.90 mm × 3.91 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Functional Block Diagram
NC / VRXD / FAULT (See Note A)
5
FAULT LOGIC
MUX (See Note A)
VCC
3
VCC
OVER
TEMPERATURE
VCC
TXD 1
DOMINANT
TIME OUT
7 CANH
6 CANL
S8
RXD 4
MODE SELECT
UNDER
VOLTAGE
VCC or VRXD (See Note B)
LOGIC
OUTPUT
DOMINANT
TIME OUT
(See Note C)
2
GND
Terminal 5 function is device dependent;
NC on SN65HVD265, VRXD for RXD output
level-shifting device on SN65HVD266, and
FAULT Output on SN65HVD267
RXD logic output is driven to 5V VCC on
5V-only supply devices (SN65HVD265,
SN65HVD267) and driven to VRXD on
output level-shifting device (SN65HVD266).
RXD (Receiver) Dominant State Time Out
is a device dependent option available only
on SN65HVD267.
1