SN65HVD265 Datasheet, PDF (1/33 Pages) Texas Instruments – Turbo CAN Transceivers | |||
|
Product
Folder
Sample &
Buy
Technical
Documents
Tools &
Software
Support &
Community
SN65HVD265, SN65HVD266, SN65HVD267
SLLSEI3A â SEPTEMBER 2013 â REVISED NOVEMBER 2015
SN65HVD26x Turbo CAN Transceivers for CAN FD (Flexible Data Rate) and Redundancy
1 Features
â¢1 Meets the Requirements of ISO11898-2
⢠Turbo CAN:
â Specified for 2-Mbps CAN FD (CAN with
Flexible Data Rate)
â Short and Symmetrical Propagation Delay
Times and Fast Loop Times for Enhanced
Timing Margin
â Higher Data Rates in CAN Networks
⢠I/O Voltage Range Supports 3.3-V and 5-V MCUs
⢠Ideal Passive Behavior When Unpowered
â Bus and Logic Terminals are High Impedance
(no load)
â Power-Up/Down With Glitch Free Operation
On Bus
⢠Protection Features
â HBM ESD Protection Exceeds ±12 kV
â Bus Fault Protection â27 V to 40 V
â Undervoltage Protection on Supply Terminals
â Driver Dominant Time Out (TXD DTO)
â SN65HVD267: Receiver Dominant Time Out
(RXD DTO)
â SN65HVD267: FAULT Output Terminal
â Thermal Shutdown Protection
⢠Characterized for â40°C to 125°C Operation
2 Applications
⢠2-Mbps Operation in CAN with Flexible Data Rate
Networks
⢠1-Mbps Operation in Highly Loaded CAN
Networks Down to 10-kbps Networks Using TXD
DTO
⢠Industrial Automation, Control, Sensors and Drive
Systems
⢠Building, Security and Climate Control Automation
⢠Telecom Base Station Status and Control
⢠SN65HVD267: Functional Safety With Redundant
and Multi-topology CAN networks
⢠CAN Bus Standards Such as CANopen,
DeviceNet, NMEA2000, ARNIC825, ISO11783,
CANaerospace
3 Description
This CAN transceiver meets the ISO1189-2 High
Speed CAN (Controller Area Network) physical layer
standard. It is designed for data rates in excess of 2
Mpbs (megabits per second) for CAN FD (CAN with
flexible data rate), greater than 1 Mbps for CAN in
short networks, and enhanced timing margin and
higher data rates in long and highly-loaded networks.
The device provides many protection features to
enhance device and CAN-network robustness. The
SN65HVD267 adds additional features, allowing easy
design of redundant and multi-topology networks with
fault indication for higher levels of safety in the CAN
system.
Device Information (1)
PART NUMBER
PACKAGE
BODY SIZE
SN65HVD26xD
SOIC (8)
4.90 mm à 3.91 mm
(1) For all available packages, see the orderable addendum at
the end of the data sheet.
Functional Block Diagram
NC / VRXD / FAULT (See Note A)
5
FAULT LOGIC
MUX (See Note A)
VCC
3
VCC
OVER
TEMPERATURE
VCC
TXD 1
DOMINANT
TIME OUT
7 CANH
6 CANL
S8
RXD 4
MODE SELECT
UNDER
VOLTAGE
VCC or VRXD (See Note B)
LOGIC
OUTPUT
DOMINANT
TIME OUT
(See Note C)
2
GND
Terminal 5 function is device dependent;
NC on SN65HVD265, VRXD for RXD output
level-shifting device on SN65HVD266, and
FAULT Output on SN65HVD267
RXD logic output is driven to 5V VCC on
5V-only supply devices (SN65HVD265,
SN65HVD267) and driven to VRXD on
output level-shifting device (SN65HVD266).
RXD (Receiver) Dominant State Time Out
is a device dependent option available only
on SN65HVD267.
1
An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications,
intellectual property matters and other important disclaimers. PRODUCTION DATA.
|
▷ |